Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: May 1, 2026
@jamespa Sorry I'm that late, I didn't get a reminder of having been cited, dunno howBravo! for the strikingly structured approach of yours. This is a...
@judith unfortunately, I completely missed your reply until now, very sorry!Your 18 000 kWh/y knock me out -- following my basic-arithmetics-approach...
Right, JamesPa, they don't, but me being nosy .... wanted to see if there's a chance of getting away without radiator swaps .... optimistically assumi...
Uh-oh, 85 kWh in 24 hours sum up to 3.5 kW in average .... perhaps the stove was meddling into the yearly result .... good you mention that.Anyway it ...
Nicely large radiators -- single layer or double? With zig-zag sheet metal dissipators on their back?When you live in an area with hard water, limesca...
Radiator .... and there it goes, my shiny theory .... so sorry, but at least I tried, and not having done so would be a shame. Keep anyway RT in mi...
@mairiA apologies myself since I didn't watch my e-mails by now.My concern is that your radiators could be hot on top but (worst case) stone cold at t...
Oh, how I love these old scientists!I'm in with your 5 kW -- thanks, that helped a lot.Overall, I enjoy this conversation very much.I do, while any ou...
Second thought, sorry:What I said about 6 kW instead of 7.5 kW against 10 kW, was under the assumption, that at 1600 or 1800 l oil per year the indoor...
No buffer, check.No re-pipe, check.6 kW would add up better imo, 10 kW doesn't at all. Big pump bringing a 200-day-per-year risk of too little demand ...
Er, nobody out there to support?I'm quite sure that my wild guesses won't help, but possible will provoke some reaction from people more skilled than ...
I read this thread from the beginning to its end.And then I read it again, thinking 'Did anybody mention return temperature RT? No, 'twas missed out.'...
- 26 Forums
- 2,618 Topics
- 61.1 K Posts
- 638 Online
- 6,994 Members
Join Us!
Worth Watching
Latest Posts
-
RE: Renewables & Heat Pumps in the News
An article on funding for heat pumps in case anyone is ...
By Jeff , 49 minutes ago
-
RE: Indevolt Batteries UK Support & Info Thread
Thanks @editor , @indevolt-uk Subject to any comments ...
By JamesPa , 9 hours ago
-
RE: Share Your Experiences with Heat Pump Manufacturer Support
@seoras Sorry to hear that. I found Vaillant very help...
By JamesPa , 9 hours ago
-
The Watchdog That Watched and Waited
On 9 January 2026, Consumer Energy Solutions collapsed ...
By Mars , 13 hours ago
-
RE: GSHP Kaput After 16 Years: New Compressor or Switch to ASHP? Advice Welcome
Cool Energy in Grimsby sell ground source heat pumps an...
By DerekDeLeon , 13 hours ago
-
RE: Valliant Heat Pump Settings
Thats arguably a sign of a good installer - they unders...
By JamesPa , 14 hours ago
-
RE: Electricity price predictions
Well, we have so many cases where rain water mixes with...
By Batpred , 15 hours ago
-
RE: Two heating zones to one zone
@profzarkov They arent obviously wrong, but the only...
By JamesPa , 17 hours ago
-
RE: Towns water feed to air source heat pump system
The DHW circuit cant be separated (well it could, you c...
By JamesPa , 17 hours ago
-
Solis AC-coupled 3kW storage inverter
Solis AC-coupled 3kW storage inverterPylontech batterie...
By MartinRobinson , 23 hours ago
-
RE: My NIBE ASHP Nightmare: No Commissioning, High Bills and a Hostile Installer
As @transparent has observed above, this is not bad, an...
By cathodeRay , 1 day ago
-
As I was reading this article Mars, I was thinking that...
By Toodles , 2 days ago
-
RE: Tell us about your Solar (PV) setup
Installed in May 2011: 16*Sharp 245 W monocrystalline p...
By txmartyn , 2 days ago
-
-
RE: Say hello and introduce yourself
That doesn't sound 'right' to me. The national Smart ...
By Transparent , 3 days ago
-
RE: Growatt battery disconnected
I doubt this will happen, but I will try and suggest it...
By Eliuccio , 3 days ago
-
Understood. That's why I decided from the outset on a ...
By JamesPa , 3 days ago
-
RE: My experience with 3 heat pump surveys: Heat Geek, British Gas & Octopus
On the litigation, I would not go there and definitely ...
By Batpred , 3 days ago
-
RE: Recommended home battery inverters + regulatory matters - help requested
I suppose if your pv inverter packs up, you have a plan...
By Batpred , 4 days ago
-
RE: New Vaillant aroTherm Plus in black - When will it come to the UK?
Firstly check you are using sound power not sound press...
By JamesPa , 4 days ago
-
That’s the solar up and running, I don’t think it’s the...
By David999 , 4 days ago
-
RE: Seeking ideas / information / commiseration - Pure Drive
I agree with @colinc that you can reuse some of it. A s...
By Batpred , 4 days ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
@toodles Im trying me best to ignore orangeman, I figur...
By Papahuhu , 5 days ago