Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

KenBone
@kenbone
Member Professional Installer
Trusted Member
Joined: Feb 6, 2024
Last seen: Nov 11, 2025
Topics: 0 / Replies: 49
Reply
RE: Is this a bad installation and is there something wrong with my Samsung heat pump?

@david999 my oh my, I'm sorry the installation is very poor,

2 years ago
Reply
RE: Pipe Work Question?

That's too tight IMO, we would use 28mm copper, or 32mm MLCP

2 years ago
Reply
Reply
RE: Grant 13kW Aerona3 - issues getting zones to temp

@crimson I have worked up there, but it is a long commute from Basingstoke.

2 years ago
Reply
RE: Samsung Gen 6 Issues with outlet temp

looks like system is in fixed flow temp not weather compensation need to change

2 years ago
Reply
RE: Grant 13kW Aerona3 - issues getting zones to temp

I've ripped all these pumps and low Loss Header out the last few days. Just a spoiler, the system still works.

2 years ago
Reply
RE: Grant 13kW Aerona3 - issues getting zones to temp

All looks a bit of a mess, where's the lagging. I was working on a Grant this week and I’m ripping out all those valves, extra pumps and low loss he...

2 years ago
Reply
RE: Volumiser placement in Vaillant Arotherm + system?

The bypass is not installed correctly, as it should incorporate the volumizer, which it doesn't.

2 years ago
Reply
RE: Why Your MCS-Certified Installer Might Not Be As Competent As You Think

Totally agree, the industry as a whole is making red tape jumps and hoops, that should not be there. The practical theory ratio is way out of balance,...

2 years ago
Reply
RE: Daikin Altherma noisy heat pump - help and advice needed

@clairelp Yes i am the same thinking, you are just a little to far away from me.

2 years ago