Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Aug 23, 2026
This seems excellent to me since I get so annoyed with current building regs of two panels on a south facing roof which could take 10. Or two on the n...
We have a 9.5kWh battery which we got in 2022 together with a further 2kW of PV. The payback time was ~7 years then, which we consider completely acce...
The timer is for if you are in expanded mode the wc is modified by switching off the heating if it’s too warm. You can have a set-back temp overnight ...
@transparent it has a virtually clear seal that can barely be seen by eye never mind on a photo. I’ve not proded it (calibrated biro test!) so I’m not...
This is the bracket supporting our 7kW Vaillant. It looks more substantial and is designed for an higher upper weight limit and has no noise we’ve hea...
Boost goes up to your normal set temperature so it depends on how cold it has got. We can see the electricity use profile so know roughly how long it ...
I totally agree that K2 are worth it. They don’t look very different to K1 or P+ and are SO much more effective. Moving to K3 is a different step in b...
I have no connection with them whatsoever but why not ask Brendon atfor advice & replacement? You’re in Cumbria and he’s well respected in the ind...
If you go into system view on the app it shows flow temperature and you’ll easily see the DHW heating which ramps to become above your DHW set tempera...
We have a 4kW array and a Sunnyboy inverter (still working very well from original) and FIT. You need to ensure you get an AC coupled inverter into th...
If after reaching its minimum level continuous operation it cycles cleaning 80% on 20% off in an hour gradually reducing its on period to just ~15min...
For my part I was overwhelmed with the total number of questions. So I’ll answer a simple one: if one ufh zone is colder then yes you get it warmer ...
- 27 Forums
- 2,750 Topics
- 64.7 K Posts
- 1,965 Online
- 7,157 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: How Accurate Is My DIY Heat Loss Calculation?
@editor Thanks Mars, I have been enjoying playing with ...
By kilgorexv , 2 hours ago
-
New Vaillant Arotherm controls link to existing thermostats ; wired vs wireless
I am feeling baffled and worried:We are having a an Aro...
By GutoFfowc , 5 hours ago
-
RE: Do I add Air Con or MVHR to existing A2W ASHP?
@rob-of-york Thank you, I’m thinking along these same l...
By Toodles , 8 hours ago
-
@Mars Good questions! The downstairs unit did the maj...
By Rob of York , 8 hours ago
-
RE: Questions about A2A for heating as well as cooling
@donciccio I would suggest that you take a "fabric-fi...
By Rob of York , 8 hours ago
-
RE: Volumisers in Heat Pump Systems: Does Placement Matter?
@dave, I think @jamespa has probably identified the mos...
By Mars , 1 day ago
-
RE: Plug and play solar. Thoughts?
My thought is simple. Bring it on and bring on plug in...
By JamesPa , 2 days ago
-
RE: Heat Geek mini store vs pump size
Yes I agree, that’s why Heat Geek have most likely sele...
By Tomtheheatingengineer , 2 days ago
-
RE: Who's your electricity provider and what's your tariff?
@chandykris Swings and Roundabouts, you win some…. ...
By Toodles , 2 days ago
-
@tomtheheatingengineer, thank you, and welcome to the f...
By Mars , 3 days ago
-
RE: HeatGeek vs Octopus surveys: puzzling disparity - any ideas why?
@majordennisbloodnok @tomtheheatingengineer For my ...
By JamesPa , 3 days ago
-
RE: Is the "divide by 2900" rule still valid?
Really flow rate is a pipework limitation not a water p...
By JamesPa , 3 days ago
-
RE: The good, the bad and the not that great – my heat pump installation
@burtis, I’ve followed this thread pretty much from the...
By Mars , 6 days ago