Search with Wattson
Activity
 
Notifications
Clear all

Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

Judith
@judith
Member
Prominent Member
Joined: Nov 28, 2023
Last seen: Aug 3, 2026
Topics: 4 / Replies: 544
Reply
RE: Vaillant Aerotherm Plus - What is Green IQ setting?

If Vaillant produced a list of all of their various variables that would be valuable!

2 years ago
Reply
RE: Minimum ASPH outputs?

A snapshot of our 7kW Vaillant was at an OAT of 18C producing 1.1kW with 40% of the time on & 60% of time off. The lowest in continuous production...

2 years ago
Reply
RE: ÀSHP heat loss - how close to perfect can we get?

We get extra heat loss on wet and windy days too, even the best heat loss model, the passive house one (which does allow for solar gain and shading) d...

2 years ago
Reply
RE: Vaillant Aerotherm Plus - What is Green IQ setting?

I too would like to read Vaillant’s explanation since it seems to just be a marketing gimmick on gas boilers and the sensocomfort is to be used on all...

2 years ago
Reply
RE: ÀSHP heat loss - how close to perfect can we get?

First “no blower test above 1ACH”. If these are done on a building site on a typical design, once this passes the rest of the houses are built the sam...

2 years ago
Reply
RE: ÀSHP heat loss - how close to perfect can we get?

Somebody above added a throw away line about air leakage through chimneys Here are some measurements (and lots of references) from BRE. Mvhr sy...

2 years ago
Reply
RE: ASHP noise, and running a high temperature heat pump at low temperature

Hi Coli, @ccap Are you planning to apply for the BUS £7500? If so you have to follow the MCS rules which mean any fossil fuel heating must be removed ...

2 years ago
Reply
RE: ASHP noise, and running a high temperature heat pump at low temperature

The high temp is only used for the legionnaires cycle and the rest of the time it should be in a system designed to be below 45 and mostly ~30C. I can...

2 years ago
Reply
RE: Advice on Vaillant Sensocomfort

The app and sensocomfort align for instantaneous readings but the app gives you the pattern over time and allows you to see heating and dhw independen...

2 years ago
Reply
RE: Simulation of ASHP with Gas boiler as part of decision process

I have a suspicion @cathoderay that when you tuned your oil heating down to reduce your bills that the temperature dropped incredibly when not on. So ...

2 years ago
Reply
RE: Advice on Vaillant Sensocomfort

I can’t answer your questions on the inactive mode since we’re not using at present (using expanded because we still have solar gain) but I can answer...

2 years ago
Reply
RE: Battery sizing - How low can you go!

if course what I should have written was INcompatible within their own range!

2 years ago