Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

Jo2255
@jo2255
Member
Active Member
Joined: Oct 6, 2026
Last seen: Oct 8, 2026
Topics: 0 / Replies: 16
Reply
RE: Missing flow temperature in Heat Geek proposal

@jamespa thats a good point. People havent really bothered much on the boiler side. I was one of them as i recently realised that you could do weath...

3 weeks ago
Reply
RE: Missing flow temperature in Heat Geek proposal

  @cathoderay I agree. This is not only about the mass produced heat pump (which we have specs for) but a bespoke design for every individu...

3 weeks ago
Reply
RE: Missing flow temperature in Heat Geek proposal

@majordennisbloodnok I think the reason for my frustration is i started my journey of heatpumps watching all the heat geek videos on YouTube. They ...

3 weeks ago
Reply
RE: Missing flow temperature in Heat Geek proposal

@editor thank you Mars. If heat geek had mentioned that traditional calculation would have your house at 6.4kW heat loss but our 1000's of installs ...

3 weeks ago
Reply
RE: Missing flow temperature in Heat Geek proposal

@editor the replies I received were as follows 1.There is the guarantee if you need it dont worry. 2.ΔT50 only refers to the radiator spec but yo...

3 weeks ago
Reply
RE: Missing flow temperature in Heat Geek proposal

@l8againagain I think you need to look into it in depth.Heat geek proposal says the heat loss are for -3.6 deg C outdoor and 21 deg C indoor temp V...

3 weeks ago
Reply
RE: Missing flow temperature in Heat Geek proposal

@jamespa However, with MCS and BUS involved, I’m struggling to understand how this works in practice. As a business, Heat Geek can size a system how...

3 weeks ago
Reply
RE: Missing flow temperature in Heat Geek proposal

@donciccio thats interesting. I really cant understand how the radiators would work in that case. What is the total output of all radiators combi...

3 weeks ago
Reply
RE: Missing flow temperature in Heat Geek proposal

@jamespa Thank you. Appreciate your response Just curious as to what would happen if I had gone with the heat geek proposal for 5kW plus with no...

3 weeks ago
Reply
RE: Missing flow temperature in Heat Geek proposal

@jamespa Not considering octopus as I do not agree with their heat loss, in addition they want scaffolding, asbestos survey as well as can only fit...

3 weeks ago
Reply
RE: Missing flow temperature in Heat Geek proposal

@jamespa Yes annual of 19,000kwh. Dont think high hot water demand as it's only 2 of us with a 1 year old. Gas boiler would definitely be degrad...

3 weeks ago
Reply
RE: Missing flow temperature in Heat Geek proposal

Thank you. Annual gas consumption about 19000kwh over the last 2 years. 2004 ideal classic non condensing original gas boiler. Range gas hob The...

3 weeks ago