Last seen: Jun 28, 2024
Hi Derek, Thank you. We've found it difficult to get good and trustworthy information and we've had some previous bad experiences with tradesmen wh...
@derek-m I hear you. The ECP F rating is apparently due to the wet electric CH system. The house was built 1990 and we moved in 4 years ago. One year ...
@editor good to hear about Grant. I’m not sure what kind of radiators we have but this is what they look like. These are to be replaced by new radiat...
@julianc I will do that - although I did have a long chat with Grant themselves and was quite impressed. We had a full and what seemed to be a frank ...
@julianc thank you. We are considering the Grant Aerona 32 17kW which has a technical spec of 61 DB and has been awarded the Quiet Mark even at that l...
There's another thread on noise levels elsewhere on this forum. Check out
@derek-m we had ice on the inside of our double glazed velux windows upstairs this winter. Once thawed the water ran in lines down the plasterwork. Th...
I've been looking at the following link which is the Quiet Mark assessment of different ASHPs and they have considered boilers too. I still don't real...
Thanks for your comments and advice Simon. Hmmmm. Not sure what to say. We are desperate for some alternative to a hugely expensive wet CH system run ...
@duncan-mac thank you. We are in Fife. So far replies from planning assistants have been of the catch 22 variety. I am simply referred back to the epl...
@editor definitely will 😊
@chaplito thank you. I’m not giving up yet. Partly because I can’t face another winter like the one we’ve just had.
- 26 Forums
- 2,417 Topics
- 54.8 K Posts
- 425 Online
- 6,096 Members
Join Us!
Worth Watching
Latest Posts
-
RE: Running my new Nibe ASHP efficiently
I didn't. I spent a while manually messing around with ...
By jamieheatpumpnew , 13 seconds ago
-
Hi, I think I’m having some issues with my Ecodan as...
By Patch321 , 9 minutes ago
-
RE: I’m glad the cold spell is over!
I comparison with the 65kWh used above yesterday was on...
By Judith , 13 minutes ago
-
RE: Sunsynk Whole House Backup Issue
@batpred I'll do my best to put together a simple diagr...
By LostandConfused , 17 minutes ago
-
RE: Recommended home battery inverters + regulatory matters - help requested
Hi, looking for help and advice as my installer is usel...
By LostandConfused , 18 minutes ago
-
RE: New Daikin 11kW Altherma 3M install - is it working as it should?
@synthbuilder Further to the above…‘What a difference t...
By Toodles , 31 minutes ago
-
RE: Octopus Cosy 12 Heat Pump Regret: Incredibly Loud, Poor Heating & Constant Hum - Help!
I should think so, I thought that pretty much universal...
By JamesPa , 59 minutes ago
-
RE: Setback savings - fact or fiction?
I'm also inclined to look into how a defrost is actuall...
By cathodeRay , 1 hour ago
-
MLCP (Multi-Layer Composite Pipe) for ASHP
@editor nope. The info you reported was sufficient for ...
By iotum , 12 hours ago
-
RE: Advice for a novice on Mitsubishi Ecodan 6kW
@robs Quick response while I'm in stationary traffic le...
By Sheriff Fatman , 12 hours ago
-
RE: Ideal HP290 14kW ASHP - how to optimise
@jamespa I wasn’t offended at all. You are very knowled...
By Davesoa , 13 hours ago
-
RE: Experience - New Build / Complete New Heating System
@vincro I would be surprised if it is much above 5 to 6...
By ASHP-BOBBA , 13 hours ago
-
RE: Post-Traumatic Heat Pump Stress Disorder
Yes bang on and maybe I can illustrate that by way of e...
By iotum , 15 hours ago
-
-
RE: Replacing my 18 month old Hitachi Yutaki ASHP
A big thank you to @jamespa for all his efforts online ...
By trebor12345 , 18 hours ago
-
RE: GSHP WOES! Midland based engineer recommendations?
@editor It is indeed for servicing. My current service ...
By Morgan , 19 hours ago
-
RE: Speedcomfort radiator fans
In case it helps Andrew Kuhne on openenergy monitor has...
By JamesPa , 20 hours ago
-
Things have gone quiet with you @drei. Any updates?