Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Sep 23, 2026
I think that there are broadly two main use cases of interest namely 'in all day' and 'out all day'. Obviously this ignores more complex shift patter...
I think this is easily made intuitive by considering the limit situation, namely a building with zero thermal mass. In such a building it's obvious t...
Good question! The total used over the year will be the sum (mathematically the integral) of the instantaneous, so on this interpretation they are s...
A deceptively simple and important question but not actually that easy to calculate (for the avoidance of doubt I don't think the previous answer was ...
Science advances through a combination of theory and experiment. True also with engineering. Fitting an equation (to experimental data) is only one ...
Sorry, I wont be doing this because tariffs change all the time. But... if night time set back saves 10-20%, but you can somehow store energy at 20%...
I assume a COP of 4 at the starting conditions (but you can adjust the value in the spreadsheet). In the forced recovery model the FT changes so the ...
@derek-m I take account of cop change due to flow temp change. I don't take account of the (generally second order and due to engineering not physics...
So far as I know that's about it. One thing I have found is that sometimes it helps to start by thinking about the emitters, or even the house, rath...
It does work harder, I have never said otherwise, and wouldn't do so because it would violate the laws of physics. I calculate the total energy suppl...
I have now had the time to have a better look at this model which I must say is very neatly laid out, congratulations. I have a couple of questions ...
True, but folding in variable oat before developing the basic theory is making it unnecessarily complex at an early stage and getting an idea based on...
- 27 Forums
- 2,774 Topics
- 65.4 K Posts
- 1,285 Online
- 7,177 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Solar Power Output – Let’s Compare Generation Figures
@downfield I was seriously considering Tide Lifestyl...
By Papahuhu , 5 hours ago
-
RE: Passiv Smart Thermostat - Help & Forum Support
Thanks Will. I'll probably be a week or so before get...
By Singlespeed , 6 hours ago
-
RE: Cooling using an air to water heat pump
From experience this summer, a single-split A2A unit on...
By Rob of York , 14 hours ago
-
@mrkfm, I’m definitely not trying to put anyone off get...
By Mars , 1 day ago
-
RE: Why are ASHP installs so expensive?
Posted by: @springswood I confess to becoming a litt...
By Rob of York , 1 day ago
-
Analysis of the economics of switching to an A2W ASHP compared to other heat sources
This post aims to analyse the economics of installing, ...
By Rob of York , 2 days ago
-
RE: Cooling with air to water heat pumps
@editor does that mean you have to have two separate ex...
By mrkfm , 2 days ago
-
RE: Starting Our Heat Pump Journey: 1962 build 3 bed detached house
Posted by: @ian-s Could always use the money saved o...
By Rob of York , 2 days ago
-
Depends on what controls the pump! Thats the whole poi...
By JamesPa , 3 days ago
-
The positive reviews keep coming in for Britain's Heat ...
By Mars , 3 days ago
-
RE: Next steps on my ASHP journey: Radiators and Pipework
I have one of these fitted which also allows you to reg...
By Old_Scientist , 3 days ago
-
RE: Recommendations in Ely (Cambs) area for Full setup checks on Nibe HP setup for House.
If they can't don't give up. Heat pumps are, in reali...
By JamesPa , 4 days ago
-
RE: Missing flow temperature in Heat Geek proposal
Yes that's what would happen by turning down the lsv to...
By JamesPa , 4 days ago
-
RE: Grant R290 DHW Cycle Interuption
It looks like some sort of short pre-run. The question...
By JamesPa , 5 days ago