Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

JamesPa
JamesPa
@jamespa
Moderator
Illustrious Member
Joined: Apr 3, 2023
Last seen: Sep 20, 2026
Topics: 27 / Replies: 5412
Reply
RE: Grant Aerona3 R32 HPIDI17 performance in low temperatures

The Vaillant Arotherm R290 does the legionella cycle natively, ie using the heat pump itself. Most (possibly all) R32 heat pumps dont, they use the...

2 years ago
Reply
RE: Totally bewildered with my ECO4 heat pump installation

I actually think its totally unfair to blame the Government entirely, whatever the colour. The fact is that any scheme of this nature (and indeed alm...

2 years ago
Reply
RE: Totally bewildered with my ECO4 heat pump installation

OK so your are getting an COP for the installation of 3.5 since it was installed, 3.6 last month and 2.95 this month. This includes both DHW and spac...

2 years ago
Reply
RE: Ideal Logic 10kW Heat Pump Pipes Noisy and Very Expensive to Run

If the controller box has a temperature sensor (I don't know but the manual should say) do insist they put it somewhere sensible! You may just want t...

2 years ago
Reply
RE: Ideal Logic 10kW Heat Pump Pipes Noisy and Very Expensive to Run

I would insist they move that too Ideally yes at least initially. However the ashp may be configured to require a contact closure in the the...

2 years ago
Reply
RE: Totally bewildered with my ECO4 heat pump installation

Just to say I'm very much agreeing with the anger and frustration with how the scheme works. It's inexcusable and nothing I am about to say is meant ...

2 years ago
Reply
RE: Grant Aerona3 R32 HPIDI17 performance in low temperatures

Agree with the above. Grant has historically provided kits for installers enabling them to treat the install more or less like a boiler, with ob...

2 years ago
Reply
RE: Ideal Logic 10kW Heat Pump Pipes Noisy and Very Expensive to Run

You are kidding me surely. No? In which case it's the first time I have heard this particular abomination, I will bear that in mind when asking ot...