Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Aug 19, 2026
It claims to use the energy integral as part of the cycling control loop, but is silent about how the defrost control loop works, so I dont know! ...
One might expect (hope) that the heat pump takes this into account in the control circuit, by accumulating differences and overshooting to compensate....
OK, so (assuming Freedom are correct) you actually have two problems. The principal one is that the max pump rate is insufficient, leading to your ou...
All agreed In detail that is true. However its a dead cert that its primary control loop adjusts the compressor frequency and fan speed to a...
I should add to the above one other thing. It is just possible that the Midea is designed for a deltaT higher than 5C at max output, high enough th...
OK wrong wording on my part. Please read 'infer' instead of 'say'. Regarding the rest of this quote please read again this comment As I ob...
Fair enough. Perhaps your daughter could be asked to contribute to the cost or reminded that she will (likely) outlive you and will thus suffer the e...
I don't think you can say 'This is not how a heat pump is supposed to run'. SOFAIK there is nothing wrong with operating a fixed flow rate (and thus ...
abut 1.5 bar, but I dont think it matters much unless you have a very tall house (it merely needs to be sufficient to ensure that negative pressure do...
Those cops sounds pretty close to what I see (7kW house, 7kW Arotherm). My energy delivered is currently tracking fairly close to what my measured ga...
- 27 Forums
- 2,746 Topics
- 64.6 K Posts
- 2,504 Online
- 7,152 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: The good, the bad and the not that great – my heat pump installation
@burtis, I’ve followed this thread pretty much from the...
By Mars , 2 hours ago
-
RE: Starting Our Heat Pump Journey: 1962 build 3 bed detached house
First time poster here but I can share my experience as...
By SCH , 7 hours ago
-
At the risk of going on: A slight side issue for a foru...
By Bart , 14 hours ago
-
RE: Is it the house or the equipment?
...which, I've found out, is pretty much impossible to ...
By Majordennisbloodnok , 15 hours ago
-
RE: Mitsubishi Ecodan FTC6 settings
The Mitsi remote thermostat should not be plugged into ...
By F1p , 1 day ago
-
RE: Do I add Air Con or MVHR to existing A2W ASHP?
@lizzie Thank you, very interesting and useful informat...
By Toodles , 1 day ago
-
RE: PV and battery long payback - sense check query
@jamespa I was just commenting on the speed, not sug...
By Batpred , 1 day ago
-
Readers here please note that Derril Water and many oth...
By Transparent , 2 days ago
-
RE: Advice on Vaillant Sensocomfort
Oops, I meant Sensocomfort (the UI to the controls)
By Batpred , 2 days ago
-
RE: Heat Pump Training vs. Real-World Installation
Our instal was very much the opposite. White haired blo...
By Batpred , 2 days ago
-
RE: Flushing system, cleaning and inhibitor
While skim reading a manual for our Vaillant HW tank, I...
By Batpred , 2 days ago
-
RE: 'Chinese Diesel Heater' to heat the home .....
Old thread but I'm new to the forum so new to me. How...
By BlizzardGreen , 2 days ago
-
I'm not sure why you would want to make it more difficu...
By JamesPa , 2 days ago