Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

JamesPa
JamesPa
@jamespa
Moderator
Illustrious Member
Joined: Apr 3, 2023
Last seen: Aug 19, 2026
Topics: 27 / Replies: 5268
Reply
RE: How much radiator capacity do I need for an air source heat pump?

Many manufacturers give an equation in the following form: output is proportional to (deltaT)^n where deltaT is the mean difference between the ...

2 years ago
Reply
RE: How much radiator capacity do I need for an air source heat pump?

First question, what's the heat loss of your house? If by any chance you have a smart meter and can get half hourly or daily gas consumption you can...

2 years ago
Reply
RE: Thinking of ripping our my IVT Greenline HT Plus C model and replacing with a gas boiler.

Further to the above I found the manual here Page 37 describes the alarm and possible reasons, of which a blocked filter is one. Page 2...

2 years ago
Reply
RE: Thinking of ripping our my IVT Greenline HT Plus C model and replacing with a gas boiler.

Do you know what the alarm means. From what you 'have been told' it sounds like a 'low flow' alarm. If it wasnt there initially then something ...

2 years ago
Reply
RE: Is My Midea Heat Pump Inherently Defective?

As a former local government employee (following a career in engineering) I realised that explaining the consequences to politicians simply and in ter...

2 years ago
Reply
RE: ASHP and how it should run and potential kw consumption?

I am planning on trialling night time 'set forward' to take advantage of cheap rate tarrif. I have no idea if it will work in practice. The challeng...

2 years ago
Reply
RE: Is My Midea Heat Pump Inherently Defective?

Thanks for that, I think there is much comfort to be drawn because of: ... with which, based on everything you have told me, I agree. My heat ...

2 years ago
Topic
Replies: 22
Views: 3741
Reply
RE: ASHP and how it should run and potential kw consumption?

I think that conditions over the last couple of days are about the worst possible - cold but very wet = lots of defrost. I too am interested in what ...

2 years ago
Reply
RE: Analysing MELcloud heat pump graphs

I'm not an ecodan expert but this looks like defrost to me. The give away is that FT goes below RT.. Conditions for defrost are about as bad as they...

2 years ago
Reply
RE: Is My Midea Heat Pump Inherently Defective?

I think you are very likely right unfortunately. This is a somewhat surprising conclusion given that the system was presumably designed by Freedom an...

2 years ago
Reply
RE: Is My Midea Heat Pump Inherently Defective?

I confess Im a bit mystified. How was the WC curve determined. If it was determined experimentally, then cycling and losses in PHE etc would be, at ...

2 years ago