Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Aug 12, 2026
@dansus To achieve a full 3kW (3000W / 13A) continuous AC feed-in into your home grid, you will need equip 1× PowerFlex 3000 and at least 1× Extra Bat...
@transparent Thanks for adding this level of accuracy to the thread.
@jamespa Hello, to guarantee 100% compliance across all UK Distribution Network Operators (DNOs) and home insurance policies, the primary and most rob...
We have noticed a few queries across our UK community regarding grid certifications (G98, G100 and G99). We want to provide complete transparency rega...
@jamespa For any battery storage or microgeneration system operating in parallel with the grid (under ENA G98 and BS 7671 Regulation 551.7 regarding l...
@editor Your summary is spot on, and you’ve captured the nuance of the current UK landscape better than most marketing copy does. The technology is ve...
@editor To answer your two specific questions directly:1. Can solar power coming through the AC-coupled Backup connection charge the battery as well a...
@old_scientist @etchedpixels This exact trade-off is why we designed the architecture of the PowerFlex 3000 the way we did:1. Instead of choking the e...
@editor @editor @jamespa @transparent You are correct. The definition of a "plug-in microgenerator" under the 27 August framework explicitly excludes...
@etchedpixels Your understanding is spot on. When connected solely via a standard household wall plug, the battery energy (whether charged from solar ...
@jamespa @transparent Thank you for quoting the scope section from the DESNZ Interim Product Specification (IPS). You are absolutely right, and we app...
@jamespa Hello! The upcoming August 27th specification regulates the maximum feed-in power to the home grid via a wall plug (capped at 800W), rather...
- 27 Forums
- 2,766 Topics
- 65.1 K Posts
- 2,936 Online
- 7,169 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Siting of the external sensor on a heatpump
I agree. However I would also (primarily) expect that ...
By JamesPa , 8 hours ago
-
RE: Next steps on my ASHP journey: Radiators and Pipework
You should (almost) always reject having a buffer, by w...
By JamesPa , 12 hours ago
-
RE: Navigating the World of Refrigerants In Heat Pumps: A Guide for Homeowners
Indeed we are invvestigating AC at present and are havi...
By Toodles , 15 hours ago
-
RE: Is it the house or the equipment?
@majordennisbloodnok I do sympathise. On the original...
By springswood , 17 hours ago
-
No, but the heat pump must be capable of delivering a S...
By JamesPa , 21 hours ago
-
Sorry to hear about the problems, its going to be somet...
By JamesPa , 22 hours ago
-
RE: Daikin ESPAltherma and Home Assistant installation
It's laziness lol The PV system is very chatty, meter...
By bobflux , 1 day ago
-
RE: Problems with sizing a replacement for a Viessmann Vitocal 200-S
R (The R Project for Statistical Computing, I use it wi...
By cathodeRay , 2 days ago
-
RE: Vaillant Arotherm Plus 7KW need a service on it
booked it with Vaillant. will use them until i can find...
By AdamK , 2 days ago
-
RE: Adventures in heat loss calculations
I have seen it stated that the declared calorific value...
By JamesPa , 2 days ago
-
RE: Two heating zones to one zone
@transparent Many thanks. The garage is fairly well ...
By Profzarkov , 3 days ago
-
RE: Vaillant Aurotherm - Heater Wire Position
Ah, good point. I need to check if this was installed i...
By Batpred , 3 days ago
-
@batpred thanks for getting a copy. Appreciate the supp...
By Mars , 3 days ago
-
RE: Tell us about your Solar (PV) setup
We have a 6.56kW solar PV system (16x 410W panels) inst...
By Rob of York , 4 days ago