I am currently refining my own smart controller for my Grant Aerona3 R32 as it has practically prehistoric controls I am now addicted to ESP32 devices...
I think my strategy will be to leave it always on during heating season and then change it to sniffing cycle for the summer. I am sure it would be con...
@steelbadger lol it just made the rest of the house hotter!
My Grant Aerona3 circulation pump is set by default to run constantly this alone has cost £150 so far this year, if it is heating season I get the uni...
Morning, On top of what everyone else I would deffo look into an apprenticeship. My boy failed all his exams at school and was pretty despondent but m...
This is one of the best explanations I have seen on here thanks! As we are currently being battered by the wind I think today is the day to update m...
I had a very similar fault, it sounded like someone took a hammer to the pipe work. It turns out they had piped the DHW incorrectly. For some reason t...
The logic currently changes the max flow temp setting via modbus to reflect the change in variables in my case if the wind is due to come from a certa...
Sorry by local I meant I have an Ecowitt weather station lol
On the Grant Aerona3 you can use the dual point function as kind of a boost button for a different point than your main zone. So if we get a sudden bl...
That is something I am thinking of implementing on my HA integration putting the ASHP in “fixed” flow temp and simply adjust that using weather foreca...
Interesting that you change the values at each end I never thought of that I have only been adjusting the max flow temp at the cold end, do you find t...
- 26 Forums
- 2,364 Topics
- 53.6 K Posts
- 194 Online
- 6,027 Members
Join Us!
Worth Watching
Latest Posts
-
RE: New Fogstar 15.5kWh upright solution
Inverters can pick up cell voltages and the overall bat...
By Transparent , 6 minutes ago
-
RE: My Powerwall 3 Consumes 3-4 kWh/Day in Self-Consumption: Is This Normal?
@editor Thank you so much for looking into this for me ...
By Caron , 23 minutes ago
-
RE: External pipework insulation
@transparent been in the heating industry f...
By David Smith , 26 minutes ago
-
Thanks, @downfield. I'll take a look at the Zemismart m...
By Majordennisbloodnok , 34 minutes ago
-
RE: Mitsubishi Ecodan R290 10kW performance
I have the CN105 'dongle' connected to my system, which...
By Sheriff Fatman , 57 minutes ago
-
RE: Solis S6-EH1P8K-L-PLUS – Why I Chose It and What I’ve Learned So Far
I've been looking at the S6-EH1P8K-L-PLUS, but put off ...
By energy9165 , 1 hour ago
-
RE: Speedcomfort radiator fans
Too expensive IMHO for a whole house, at this point do ...
By JamesPa , 1 hour ago
-
RE: Say hello and introduce yourself
@velcro welcome to the forums. Please feel free start a...
By Mars , 14 hours ago
-
Daikin EDLA11D3V3 DHW Settings
I have a newly installed EDLA11D3V3 which I'm still get...
By Velcro , 15 hours ago
-
RE: Setback savings - fact or fiction?
Will come back to the above points, but for now, I've j...
By cathodeRay , 15 hours ago
-
@jamespa I have found that it comes as a shock when we ...
By Toodles , 17 hours ago
-
RE: Need Help Optimising My Rushed ECO4 Install: 12kW Bosch Heat Pump
Hi @mickamills . Welcome to the forum. It sounds like...
By bontwoody , 19 hours ago
-
RE: Midea ASHP – how to set weather compensation
@curlykatie did you get sorted with this?
By MickaMills , 19 hours ago
-
RE: Octopus Cosy Heat Pump Owners & Discussion Thread
The FT levels off at either the set point OR the minimu...
By AndrewJ , 2 days ago
-
RE: MyVaillant Connect Regular Disconnect
Thanks. Yes, if the time is consistently 11pm every nig...
By buckwem , 2 days ago
-
RE: Who's your electricity provider and what's your tariff?
@transparent Thanks, this helps. Could it be that St...
By Batpred , 2 days ago
-
RE: Clivet ASHPs and weather compensation
Simon did share a lot of very helpful advice. On furthe...
By ambris , 2 days ago
-