Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

F1p
@f1p
Member
Estimable Member
Joined: Oct 27, 2025
Last seen: Jun 12, 2026
Topics: 1 / Replies: 116
Reply
RE: Ecodan Pump Issues… Circulation pump turns off when heat pump compressor turns off

  This is the 'OUTLET' from the external unit yes (so flow, before 3 way valve), as the magnetic filter is shown just below  

5 months ago
Reply
RE: Ecodan Pump Issues… Circulation pump turns off when heat pump compressor turns off

@patch321 No, not standardThe valve below it is the end of the Pre-Plumbed cylinder, this has been fitted by your installer

5 months ago
Reply
RE: Advice for a novice on Mitsubishi Ecodan 6kW

  In the Home Assistant firmware the data points are between 2s and 25s depending how important the values are, e.g. compressor frequency, flow...

5 months ago
Reply
RE: Ecodan Pump Issues… Circulation pump turns off when heat pump compressor turns off

@patch321 You are going to have a bit of a fight on your hands I'm afraid if you are oversized and particularly in warm weather. the Ecodan logic...

5 months ago
Reply
RE: Ecodan Pump Issues… Circulation pump turns off when heat pump compressor turns off

@patch321 1. Why do the circulation pumps turn off soon after the compressor stops? In compensation curve or fixed flow, the result of a flo...

5 months ago
Reply
RE: Advice for a novice on Mitsubishi Ecodan 6kW

Frost Protect/Freeze Stat is an operation mode, where Defrost is a multi-stage status flag (however i only see two used).In the firmware i inject defr...

5 months ago
Reply
RE: Advice for a novice on Mitsubishi Ecodan 6kW

@sheriff-fatman It appears Output Power = 0kW because there was a DeltaT of 0Which doesn't appear correct because it was 4C according to the data.L...

5 months ago
Reply
RE: Melpump Users Anywhere?

A sneak preview of the onboard compensation curve designer that is going to be built into MELPump for use only with the adapter.Still tweaking the des...

5 months ago
Reply
RE: My Powerwall 3 Consumes 3-4 kWh/Day in Self-Consumption: Is This Normal?

I have done some investigation into this previously, I have 3 data sources - Tesla measurements (instantanious), Tesla App History and also some high ...

6 months ago
Reply
RE: Mitsubishi Ecodan R290 10kW performance

  It's generation dependent, the latest FTC7 (touchscreen) have the ability to modulate PWM based on OAT.  

6 months ago
Reply
RE: Mitsubishi Ecodan Auto Adaption trial to stop cycling.

The interval you talk of, i think, will be 60min for any thermostat changes to take effect - which might not be exactly what you want.E.g. you turn th...

6 months ago
Reply
RE: Configuring third party dongle for Ecodan local control

However, I've found the documentation doesn't work exactly as laid out and I needed to make a tweak. Please let me know what this was so I can upd...