Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

F1p
@f1p
Member
Estimable Member
Joined: Oct 27, 2025
Last seen: Aug 11, 2026
Topics: 1 / Replies: 121
Reply
RE: Hoped for improvements not being realised on my Mitsubishi heat pump

The DeltaT is pretty high, by the sounds of it flow rate too low for the outdoor unit sizePump might be set on 5 - but potentially it needs replaced w...

7 months ago
Reply
RE: Hoped for improvements not being realised on my Mitsubishi heat pump

@davidalgarve The settings look correct, and i see you now have movement in the value - so it appears to be working. I know there is some filteri...

7 months ago
Reply
RE: Hoped for improvements not being realised on my Mitsubishi heat pump

The default for an unpaired or incorrectly assigned thermostat is also 20, could you further check: Initial settings > Room sensor settings > ...

7 months ago
Reply
RE: Hoped for improvements not being realised on my Mitsubishi heat pump

Finally, surely there must be some significance in the fact that the room temperature, as relayed from the wireless controller, shows a steady 20C whe...

7 months ago
Reply
RE: Hoped for improvements not being realised on my Mitsubishi heat pump

You can select a date in the past which perhaps reflects best the issue you see, and then Share that day - see the buttons to press outlined in red bo...

7 months ago
Reply
RE: Hoped for improvements not being realised on my Mitsubishi heat pump

@davidalgarve Would you be willing to in MELPump > Detailed Report > Share As URL So we can see a detailed and interactive chart please?

7 months ago
Reply
RE: Hoped for improvements not being realised on my Mitsubishi heat pump

  I haven't been able to locate the outdoor unit model number here or in your signature, but a 120 in the part number suggests it's 12kW rather...

7 months ago
Reply
RE: Ecodan Zone 2 Mitshibishi thermostat Auto Adapt

With a bit of work you could probably create a template to take the difference between a room temperature sensor and target and adjust one the offset ...

7 months ago
Reply
RE: Melpump Users Anywhere?

I think this was resolved last night, it was for me anyway  

7 months ago
Reply
RE: Melpump Users Anywhere?

@sheriff-fatman Yes, that's a good point - this conversation is related only to the Beta feature of the onboard compensation curve Further to that, ...

7 months ago
Reply
RE: Melpump Users Anywhere?

I reviewed some device logs and there is a mistake in the JSON schema being sent by MELPump so the adapter is not taking any action on it.  

7 months ago
Reply
RE: Melpump Users Anywhere?

@sheriff-fatman has a meltdown when it has to adjust slightly at 5°C and starts cycling I have a similar sort of issue, although at a slightl...

7 months ago