Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Sep 19, 2024
I suspect that you do not require a valve arrangement as you suggest. Once the modifications have been completed, with the buffer tank now acting as a...
@transparent At last, it would appear that we now have some 'grown-up' involved in the decision making, rather than merely the occupants of the West...
So it's your fault there is too much energy available? 😋
@ianmk13 It could be that NGED are trying to encourage consumers to pay them to install a 3 phase supply, which would be financially advantageous fo...
@johnmo I didn't say it was a simple solution, but I feel it is probably better than paying wind farm operators not to generate. In Winter the vas...
Looking at the charts, I suspect that your heat pump was only running the primary water pump but not the compressor, but without being able to observe...
I do believe that Siemens are developing modification for their gas turbines so that they can burn pure Hydrogen.
Your present system configuration requires the Honeywell thermostat to stop and start your secondary water pump, otherwise you would fail to get any ...
@jamespa You may find this of interest.
Running a Combined Cycle Gas Turbine (CCGT) on hydrogen produces water vapour not CO2, so there would be no need for Carbon Capture (CC).
@iantelescope The fact that your heat pump was drawing little power would indicate that it was not performing a defrost cycle during the period show...
Would you think that to be cost effective?
- 27 Forums
- 2,733 Topics
- 64.2 K Posts
- 843 Online
- 7,138 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Aircon - in listed buildings
@etchedpixels thanks for giving such a full and helpful...
By GrahamF , 2 hours ago
-
RE: Questions about A2A for heating as well as cooling
Is it fairly open plan or subdivided into lots of small...
By JamesPa , 4 hours ago
-
RE: Acond heat pump failed after four years - diagnostic quote £940 plus VAT
Another idea if the above don't work - there are compan...
By downfield , 4 hours ago
-
RE: Love veg, hate watering cans
They have their downsides but boreholes are great in th...
By ian33a , 5 hours ago
-
RE: Who's your electricity provider and what's your tariff?
@old_scientist The service engineer powered down the ex...
By Papahuhu , 6 hours ago
-
RE: Issue with Samsung Cascade System
@jamespa It's a funny system, but was out only option l...
By Renewables345 , 10 hours ago
-
RE: HeatGeek vs Octopus surveys: puzzling disparity - any ideas why?
Thanks, I like the chart, very helpful and this will de...
By baroquebank , 1 day ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
Production resumed to normal once the issue ...
By MK4 , 1 day ago
-
RE: Digest of UK Energy Statistics
That sounds painful. It would be much better to charg...
By Transparent , 2 days ago
-
Hole diameter is small but hole length is also very sma...
By bobflux , 2 days ago
-
RE: Are Wind Turbines Really “Losers”?
We were sailing near a wind farm in the North Sea last ...
By Jeff , 2 days ago
-
@trebor12345 The idea is to ensure that Powerwall knows...
By Toodles , 2 days ago
-
RE: Indevolt Batteries UK Support & Info Thread
'hard limited' could be in 'admin' password protected s...
By JamesPa , 3 days ago