Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Sep 19, 2024
I suspect that you do not require a valve arrangement as you suggest. Once the modifications have been completed, with the buffer tank now acting as a...
@transparent At last, it would appear that we now have some 'grown-up' involved in the decision making, rather than merely the occupants of the West...
So it's your fault there is too much energy available? 😋
@ianmk13 It could be that NGED are trying to encourage consumers to pay them to install a 3 phase supply, which would be financially advantageous fo...
@johnmo I didn't say it was a simple solution, but I feel it is probably better than paying wind farm operators not to generate. In Winter the vas...
Looking at the charts, I suspect that your heat pump was only running the primary water pump but not the compressor, but without being able to observe...
I do believe that Siemens are developing modification for their gas turbines so that they can burn pure Hydrogen.
Your present system configuration requires the Honeywell thermostat to stop and start your secondary water pump, otherwise you would fail to get any ...
@jamespa You may find this of interest.
Running a Combined Cycle Gas Turbine (CCGT) on hydrogen produces water vapour not CO2, so there would be no need for Carbon Capture (CC).
@iantelescope The fact that your heat pump was drawing little power would indicate that it was not performing a defrost cycle during the period show...
Would you think that to be cost effective?
- 27 Forums
- 2,748 Topics
- 64.7 K Posts
- 1,907 Online
- 7,156 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Volumisers in Heat Pump Systems: Does Placement Matter?
@dave, I think @jamespa has probably identified the mos...
By Mars , 11 hours ago
-
@kilgorexv, I actually think doing your own calculation...
By Mars , 11 hours ago
-
RE: Plug and play solar. Thoughts?
My thought is simple. Bring it on and bring on plug in...
By JamesPa , 1 day ago
-
RE: Heat Geek mini store vs pump size
Yes I agree, that’s why Heat Geek have most likely sele...
By Tomtheheatingengineer , 2 days ago
-
RE: Who's your electricity provider and what's your tariff?
@chandykris Swings and Roundabouts, you win some…. ...
By Toodles , 2 days ago
-
@tomtheheatingengineer, thank you, and welcome to the f...
By Mars , 2 days ago
-
RE: HeatGeek vs Octopus surveys: puzzling disparity - any ideas why?
@majordennisbloodnok @tomtheheatingengineer For my ...
By JamesPa , 2 days ago
-
RE: Do I add Air Con or MVHR to existing A2W ASHP?
There is scope for product development here. I for one...
By JamesPa , 2 days ago
-
RE: Is the "divide by 2900" rule still valid?
Really flow rate is a pipework limitation not a water p...
By JamesPa , 3 days ago
-
RE: The good, the bad and the not that great – my heat pump installation
@burtis, I’ve followed this thread pretty much from the...
By Mars , 5 days ago
-
RE: Starting Our Heat Pump Journey: 1962 build 3 bed detached house
First time poster here but I can share my experience as...
By SCH , 6 days ago
-
RE: Is it the house or the equipment?
...which, I've found out, is pretty much impossible to ...
By Majordennisbloodnok , 6 days ago