Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Sep 19, 2024
@cathoderay Yes, you are probably correct to add fuel burnt. The idea of using a fixed LWT of 50C was as a temporary measure, to possibly make it ...
Hi Mars, I have had a further thought as to what may have been occurring in your system when running on weather compensation during milder condition...
@cathoderay For kW and kWh, kW is the rate at which energy is being used, whilst kWh is the quantity of energy used. Think mph is kW, whilst miles...
Hi Gavin, Obviously you need to set the slope of the weather compensation to the requirements of your particular home. I would suggest that you star...
@cathoderay Measuring the temperature of pipework isn't the most useful way of finding out where the heat energy is being distributed, since pipewor...
Hi Mars, Looking down at the top of the valve, clockwise is closing and anticlockwise is opening.
Hi Gavin, Is yours a newly installed system and do you know if it has been configured for weather compensation control or with the addition of auto ...
@cathoderay As you state, in theory it should all work correctly, but lets try to apply some 'real World' aspects. The manufacturer's performance ...
@alexelk Hi Alex, Welcome to the forum and I am sorry to hear about your high costs. For the forum members to be able to help could you please p...
@cathoderay Here are a few things to check and confirm. Is the pump in the secondary circuit running continuously or switching on and off with the...
@cathoderay Are you ready for the maths? The Specific Heat Capacity of water is approximately 4200 Joules (J), which means that it takes approxima...
@cathoderay I would suggest that you have a close look around your system for any form of pressure relief valve, since as far as I am aware one shou...
- 27 Forums
- 2,808 Topics
- 66.3 K Posts
- 3,584 Online
- 7,212 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Boiler Upgrade Scheme funding reduced by circa £750 million in 2026 budget
Well spotted, even if it is less than welcome news. &...
By cathodeRay , 5 minutes ago
-
RE: The Changing Jet Stream Could Challenge UK Air Source Heat Pumps
@susannasaunders When you come to get quotes for A2A...
By Rob of York , 38 minutes ago
-
RE: Say hello and introduce yourself
Perhaps it is time for an update on ‘our’ project. We h...
By Toodles , 55 minutes ago
-
RE: Marvel Heating liquidation
The interesting thing about the IBG: when I called them...
By davidnolan22 , 15 hours ago
-
RE: Vaillant ecoTEC Plus - Flow Temp and Set Up
JamesPa The chart explains well how the heat curve an...
By trebor12345 , 1 day ago
-
RE: Free app: run the immersion / heat pump from Growatt battery & solar surplus – no Home Assistant
Please bear in mind, everyone, that in order to use thi...
By Majordennisbloodnok , 2 days ago
-
RE: The good, the bad and the not that great – my heat pump installation
@burtis Thanks for posting this and Im so pleased you ...
By JamesPa , 2 days ago
-
RE: I need help with Ecodan ASHP
@f1p It turns out there have been a solar panel install...
By Andris , 3 days ago
-
RE: 15kw pump for 225m2 1990's house - over kill?
@seaviews your installer would be right to say that the...
By GrahamF , 3 days ago
-
RE: Tradespeople on Their Phones: What’s Acceptable When They’re Working in Your Home?
Actually, that's a very important point. I've only ev...
By Majordennisbloodnok , 3 days ago
-
RE: Aerotherm and weather compensation
These are likely inked. The basic explanation is tha...
By JamesPa , 3 days ago
-
RE: Electrical works for air to air heat pump
agree with above. I have not had extra costs added wh...
By Batpred , 3 days ago
-
Good to hear that you found a solution. Absolutely a...
By Batpred , 3 days ago
-
RE: Are there any comparisons of DHW heat stores around?
@sarahemmm I have done things the opposite way round I ...
By Toodles , 4 days ago