Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Sep 19, 2024
@cathoderay Yes, you are probably correct to add fuel burnt. The idea of using a fixed LWT of 50C was as a temporary measure, to possibly make it ...
Hi Mars, I have had a further thought as to what may have been occurring in your system when running on weather compensation during milder condition...
@cathoderay For kW and kWh, kW is the rate at which energy is being used, whilst kWh is the quantity of energy used. Think mph is kW, whilst miles...
Hi Gavin, Obviously you need to set the slope of the weather compensation to the requirements of your particular home. I would suggest that you star...
@cathoderay Measuring the temperature of pipework isn't the most useful way of finding out where the heat energy is being distributed, since pipewor...
Hi Mars, Looking down at the top of the valve, clockwise is closing and anticlockwise is opening.
Hi Gavin, Is yours a newly installed system and do you know if it has been configured for weather compensation control or with the addition of auto ...
@cathoderay As you state, in theory it should all work correctly, but lets try to apply some 'real World' aspects. The manufacturer's performance ...
@alexelk Hi Alex, Welcome to the forum and I am sorry to hear about your high costs. For the forum members to be able to help could you please p...
@cathoderay Here are a few things to check and confirm. Is the pump in the secondary circuit running continuously or switching on and off with the...
@cathoderay Are you ready for the maths? The Specific Heat Capacity of water is approximately 4200 Joules (J), which means that it takes approxima...
@cathoderay I would suggest that you have a close look around your system for any form of pressure relief valve, since as far as I am aware one shou...
- 27 Forums
- 2,744 Topics
- 64.5 K Posts
- 828 Online
- 7,148 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Who's your electricity provider and what's your tariff?
@papahuhu Yup, and our daughter was sitting in her back...
By Toodles , 18 hours ago
-
@DavidB, I think @Majordennisbloodnok has already naile...
By Mars , 20 hours ago
-
RE: Indevolt Batteries UK Support & Info Thread
Thanks, however that's an answer to a subtly different ...
By JamesPa , 2 days ago
-
RE: Flushing system, cleaning and inhibitor
Yes, my 50L volumiser uses the two lower ports, so ther...
By Old_Scientist , 2 days ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
@toodles Such elegant symmetry. look at my lumpy bag of...
By Papahuhu , 3 days ago
-
RE: PV and battery long payback - sense check query
Quite probably not, but you can get a 32A relay and a S...
By JamesPa , 3 days ago
-
RE: Starting Our Heat Pump Journey: 1962 build 3 bed detached house
@ian-s Look forward to making contact soon! Regards, To...
By Toodles , 3 days ago
-
I don't notice mine defrosting, and most of the time Im...
By JamesPa , 4 days ago
-
RE: Do I need to change the control unit when replacing my Ecodan Air Source Heat Pump
Kind of you, @calumm, but it was @f1p who did the heavy...
By Majordennisbloodnok , 4 days ago
-
RE: Electricity price predictions
2. As EV ownershp increases it'll certainly increase de...
By EtchedPixels , 5 days ago
-
I meant to say I cannot register my kit at Energyplus… ...
By Batpred , 5 days ago
-
RE: HomeTherma Is Live: A New Home-Energy Platform Built Around the Homeowner
Signed up!
By bobflux , 6 days ago