Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Sep 19, 2024
One of the most important factors, along with a good level of insulation, is the heating capacity of the heat emitters. Larger heat emitters can trans...
@cathoderay One way to check would be to switch your system to fixed LWT at the present value, and see if the obtained value changes or remains 'fix...
Not exactly scientific testing procedure, but quite interesting. A more scientific method would be to have two identical heat pumps, one in a cold wel...
@cathoderay I am not certain what the value of byte 14 is, please provide the message body.
@cathoderay I appreciate what you are trying to achieve, but first we need to understand the structure and method by which the present 'available' d...
You have already proved that the heat pump is badly sited, since the colder discharge air is being drawn into the intake. Heat pumps are designed to o...
@cathoderay Tracing the code for tank_actual_temperature in C3/device.py, the following is shown. custom_components/midea_ac_lan/midea/devices/c3/...
That test would seem to prove that the data in the message is only being read from the Midea controller, but it is not being written to the controller...
Now try changing one of the 'setting' values to see if that gets overwritten. class MideaC3Device(MiedaDevice): DeviceAttributes.dhw_temp_max: 60...
Okay, try changing the value to something like 100, to see if that value appears in the message or whether it is overwritten by the true value.
@cathoderay Continue the testing procedure in C3/message.py, as shown below. class C3MessageBody(MessageBody): # self.tank_actual_temperature =...
@cathoderay Once the previous test has been completed, then remove the comment and comment the following line as shown below. class MideaC3Device(...
- 27 Forums
- 2,741 Topics
- 64.3 K Posts
- 1,204 Online
- 7,144 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Do I need to change the control unit when replacing my Ecodan Air Source Heat Pump
@majordennisbloodnok - thanks so much. That has been...
By CalumM , 4 hours ago
-
We have large radiators as our emitters. Room temp is 2...
By Old_Scientist , 6 hours ago
-
RE: Electricity price predictions
2. As EV ownershp increases it'll certainly increase de...
By EtchedPixels , 7 hours ago
-
I meant to say I cannot register my kit at Energyplus… ...
By Batpred , 7 hours ago
-
RE: Indevolt Batteries UK Support & Info Thread
@indevolt-tech When you say 'dedicated switched fused ...
By JamesPa , 12 hours ago
-
RE: PV and battery long payback - sense check query
So if it helps I was recently quoted about 8 grand for ...
By EtchedPixels , 1 day ago
-
RE: HomeTherma Is Live: A New Home-Energy Platform Built Around the Homeowner
Signed up!
By bobflux , 2 days ago
-
RE: Has anyone seen this problem before? Huge anticycling times
Oh dear. Glad it was replaced. I have been mighty imp...
By JamesPa , 3 days ago
-
RE: Can I start an argument about buffer tanks please? 🙂
Dont, just adjust the LSVs to get different temperature...
By JamesPa , 3 days ago
-
RE: Heat pump running costs – what has actually worked for you?
I installed the air source heat pump in January 2026, i...
By bobflux , 3 days ago
-
RE: Grant Aerona Air to Water R290 6.5 kW - Quiet Mark and Silent Running
Thats all interesting. DHW on my Vailant seems to respe...
By JamesPa , 4 days ago