@jamespa many thanks. will do
@jamespa thanks for the advice. If I am tweaking the curve for low temps, should I first increase the Maximum outgoing water temperature in Heating mo...
@grantmethestrength I'd be interested to hear more about your Wavesure Modbus to ethernet adapter install. I can provide my email if you don't want to...
@grantmethestrength 2101 is irrelevant is it not if the WC is on (2100)? On an aside, it sounds like you had a better installer. Have you been told ...
We have a Grant Aerona3 as well. We are not on Octopus Cosy as I am still learning the system and am not sure if it is better to warm the house on the...
@damonc interesting! It all depends on your house I reckon. If your insulation is not wonderful as ours isn't, 2C might be reached too quickly and if ...
I realise now that this hysterisis setting is controlling when the heating comes on e.g. Heating : Outgoing water temp ≥ Water set point (parameter 21...
@damonc If we are talking about a Grant Aerona3, 2141 is not the frost protection hysterisis - those settings are in group 43. 2141 controls when the ...
There is one other setting in the Grant heat curve group which is the Hysteresis of water set point in heating and the default is 8C. Am I right that...
Many thanks for that advice. I did think it was a bit crazy. The previous owners would not made these settings as they were in their 80s.... I have ...
- 26 Forums
- 2,104 Topics
- 46.3 K Posts
- 138 Online
- 3,393 Members
Latest Posts
-
RE: Location of hot water isolation valve on cylinder
@transparent Thank you so much and very helpful. Earlie...
By rossowheels , 12 hours ago
-
RE: Who's your electricity provider and what's your tariff?
@toodles Indeed. On a tariff such as IOF where import a...
By Old_Scientist , 13 hours ago
-
RE: Ecodan consuming 100kwh per day in new build!!!
It does indeed look like that, @skyefarmer. There is ...
By Majordennisbloodnok , 19 hours ago
-
RE: Plug and play solar. Thoughts?
Have a read of my previous posts on so-called Balcony S...
By Lucia , 2 days ago
-
@editor @bart Hi, I can see a few problems with your in...
By Brendon Uys , 2 days ago
-
RE: Compressor attempts start but fails - Nibe Fighter 2005 8kW
"To tell you the truth, I don't know if HAL is homicida...
By Scalextrix , 2 days ago
-
The Importance of Radiator Balancing for Efficient Heating: Introducing the Flow Regulating Valve
It’s fascinating to watch how low-temperature heating i...
By Mars , 3 days ago
-
RE: Servicing Hitachi HP in rural Somerset
I'd give GreenGenUK a call or email them: sales@greenge...
By Mars , 3 days ago
-
RE: Heating coming on when not required
I played with a max heating temp but there is a world o...
By JamesPa , 3 days ago
-
RE: Pressure drop Primary circuit
I've always regarded topping up heating systems as my j...
By JamesPa , 3 days ago
-
RE: Heat pump solutions and/or installer recommendations for France
I’d travel to France for work if you were struggling wi...
By Damon Blakemore , 4 days ago
-
RE: 5 Star Service from Havenwise
That's always a danger with any new good idea, @morgan....
By Majordennisbloodnok , 4 days ago
-
Have your say in the Renewable Heating Hub Awards
It’s time to celebrate the best (and call out the worst...
By Mars , 4 days ago
-
-
RE: Mitsubishi cycling while on chilled water output
@iaack yes there's no denying that cold air sinks! I s...
By downfield , 5 days ago
-
RE: Weather compensated secondary circuits with Biomass
@andycoo that flooring sounds ideal. Extra volume is ...
By Sune , 5 days ago