Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: May 14, 2026
@jamespa many thanks. will do
@jamespa thanks for the advice. If I am tweaking the curve for low temps, should I first increase the Maximum outgoing water temperature in Heating mo...
@grantmethestrength I'd be interested to hear more about your Wavesure Modbus to ethernet adapter install. I can provide my email if you don't want to...
@grantmethestrength 2101 is irrelevant is it not if the WC is on (2100)? On an aside, it sounds like you had a better installer. Have you been told ...
We have a Grant Aerona3 as well. We are not on Octopus Cosy as I am still learning the system and am not sure if it is better to warm the house on the...
@damonc interesting! It all depends on your house I reckon. If your insulation is not wonderful as ours isn't, 2C might be reached too quickly and if ...
I realise now that this hysterisis setting is controlling when the heating comes on e.g. Heating : Outgoing water temp ≥ Water set point (parameter 21...
@damonc If we are talking about a Grant Aerona3, 2141 is not the frost protection hysterisis - those settings are in group 43. 2141 controls when the ...
There is one other setting in the Grant heat curve group which is the Hysteresis of water set point in heating and the default is 8C. Am I right that...
Many thanks for that advice. I did think it was a bit crazy. The previous owners would not made these settings as they were in their 80s.... I have ...
- 26 Forums
- 2,676 Topics
- 62.6 K Posts
- 182 Online
- 7,090 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
Why do you want to maintain a specific deltaT? The out...
By JamesPa , 6 minutes ago
-
RE: Heat pump installation quotations
@batpred Excellent, thank you very much!
By sttpd1917 , 37 minutes ago
-
Hopefully this will answer your question. To...
By ASHP-BOBBA , 37 minutes ago
-
RE: Help me keep the faith with my air source heat pump installation
I would be interested to find out if others do this and...
By ASHP-BOBBA , 46 minutes ago
-
Harvest Thermal - ASHP with a smart thermal battery
I thought people here might find this interesting, even...
By springswood , 2 hours ago
-
Don't you dare. You just carry on as you are; as @batpr...
By Majordennisbloodnok , 3 hours ago
-
RE: Heat pump design review please: 5 kW Vaillant aroTHERM Plus heat pump
@ragtime27 some rooms in our house only have one place ...
By Judith , 3 hours ago
-
@mkz, that's very helpful. Even if Urban Plumber are no...
By Majordennisbloodnok , 6 hours ago
-
RE: Several AC coupled batteries
That is a good point, a manufacturers can stop trading,...
By Batpred , 6 hours ago
-
RE: Indevolt Batteries UK Support & Info Thread
Hi @hanno - good question. The range of hybrid invert...
By Transparent , 7 hours ago
-
RE: GivEnergy inverter tripping due to over-voltage?
@transparent the inverter was installed in 2021 and afa...
By Tim441 , 7 hours ago
-
RE: Say hello and introduce yourself
I hope so, @toodles. It's not often that we see a situa...
By Majordennisbloodnok , 11 hours ago
-
RE: Electricity price predictions
Good point, I do expect the bonus of putting my energy ...
By Batpred , 1 day ago
-
RE: Daikin ESPAltherma and Home Assistant installation
@bash, something we haven't touched on already relates ...
By Majordennisbloodnok , 1 day ago