RE: Has anyone seen this problem before? Huge anticycling times

Hi all, the issue has been resolved (fingers crossed) for me. It took two Vaillant engineer visits - they replaced the control board on the front rig...

4 months ago
Reply
RE: Has anyone seen this problem before? Huge anticycling times

@cg360 Hi thanks for replying - unfortunately my unit is now showing the same issue as before. Multiple sensor faults and massive anti-cycle times. ...

5 months ago
Reply
RE: Has anyone seen this problem before? Huge anticycling times

@editor Yes it is indeed out of action. Luckily the cold weather hasn't really started yet and the engineer is booked in for Thursday so hopefully wi...

5 months ago
Reply
RE: Has anyone seen this problem before? Huge anticycling times

@editor In the end a Vaillant engineer came out and was a bit mystified, but replaced the main PCB in the front top right corner of the unit. Since t...

5 months ago
Reply
RE: Has anyone seen this problem before? Huge anticycling times

Hi there, I'm very curious if you got this resolved? I have a new Vaillant Arotherm Plus that is exhibiting the exact same problem (multiple faults, ...

7 months ago
Share:

Join Us!

Heat Pump Dramas?

Thinking about installing a heat pump but unsure where to start? Already have one but it’s not performing as expected? Or are you locked in a frustrating dispute with an installer or manufacturer? We’re here to help.

Pre-Installation Planning
Post-Installation Troubleshooting
Performance Optimisation
✅ Complaint Support (Manufacturer & Installer)

👉 Book a one-to-one consultation now.

Latest Posts

x  Powerful Protection for WordPress, from Shield Security
This Site Is Protected By
Shield Security