Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Oct 12, 2024
@transparent At the risk of promoting commercial content, I've just ordered class T fuses and holder from shunts.com; for 5 x 150A Littelfuse JLLN...
Interesting; I did see "hydrobox"/"hydro kit" for a couple of the VRF units (Panasonic and LG), and have found the Argo iSeries (looks to have been ar...
The pipework is at best 10mm microbore, but with sharp turns everywhere the effective flow will be much less. Also the pipework is totally uninsulated...
Indeed, but I'm not sure air conditioning counts as a heat pump for planning purposes. At least the air-con engineer who visited site did not think pl...
I filled in the MCS calculation spreadsheet by myself and came to a figure of around 7.1kW for this 2 bedroom Victorian terrace (two up, two down) wit...
I just received a quote to add air-con to the whole of our 2 bedroom terrace house (to replace the central heating which operates on microbore); the s...
Yes, I was considering Taixi MCCB (TXCM1B or TXCM1Z) from Aliexpress. There is just a hint of doubt in my mind about the provenance and manufacturing ...
Yes our upstairs rooms were pretty warm too. On Monday afternoon I was in the loft with a solar installation engineer; it was pretty unpleasant up the...
I confirmed with a Seplos tech-support person that these are 400A Zeeman ANMH fuses; they have an interrupt rating of 2,000A@80V DC. Has anyone perfor...
@transparent Could I quickly ask about the no-load draw of the Growatt SPF5000ES. The manual lists it as < 60W; does this tie in with your experien...
I'm going to use Growatt SPF5000ES in my system, so this thread is relevant to me. However my plan is for 2 inverters and 2 (possibly 3 in the future)...
Yes, I get the impression that were I to get the SPF5000ES the modbus protocol would be the way ahead (e.g. UtiChargeStart/UtiChargeEnd/MaxChargeCurr)...
- 27 Forums
- 2,769 Topics
- 65.3 K Posts
- 1,493 Online
- 7,172 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Why are ASHP installs so expensive?
@rob-of-york I’m firmly with you on this, and it’s a co...
By Mars , 7 minutes ago
-
RE: Heat Pump deployment statistics: June 2026
To my eyes, sat behind all of this is a basic policy ma...
By Temperature_Gradient , 16 hours ago
-
Thank you @majordennisbloodnok – that means a lot, part...
By Mars , 20 hours ago
-
We’ve just passed 20 million forum views! 🎉
It's official. The Renewable Heating Hub forums have of...
By Mars , 20 hours ago
-
RE: Missing flow temperature in Heat Geek proposal
That calculation is reasonable, output is proportional ...
By JamesPa , 22 hours ago
-
RE: Recommendations in Ely (Cambs) area for Full setup checks on Nibe HP setup for House.
Have you looked at the Nibe website? They list their ap...
By Lizzie , 24 hours ago
-
RE: Who's your electricity provider and what's your tariff?
@batpred When the raw material input has increased in c...
By Papahuhu , 2 days ago
-
We kept ours and Heat Geek would have been in touch if ...
By Batpred , 3 days ago
-
RE: Starting Our Heat Pump Journey: 1962 build 3 bed detached house
@ian-s I would encourage you to have a conversation ...
By Rob of York , 3 days ago
-
RE: Is it the house or the equipment?
Thanks @jamespa The last hard to fix draughts in the...
By springswood , 3 days ago
-
RE: Vaillant Arotherm – Using Heating
@l8again Mine is typically using 11w including the i...
By Batpred , 3 days ago
-
RE: Next steps on my ASHP journey: Radiators and Pipework
If you have a flowmeter and two temperature probes, the...
By bobflux , 3 days ago
-
RE: Siting of the external sensor on a heatpump
@jamespa Absolutely. Even if the same mistake was mad...
By Batpred , 4 days ago
-