Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Nov 25, 2026
Assume flow from the heat source is higher than flow to the load. 1- Left is what happens "in theory on paper". 2- Middle is what actually happens...
You don't have to run the heat pump with a deltaT of 5°C, you can just run it at deltaT 10 or more, with lower flow rate. 5°C is a bit more efficient,...
Hole diameter is small but hole length is also very small. So there is flow restriction, but only over a short length, resulting in much less pressure...
That's well done. Cable is the correct type (LIYCY = 2x stranded copper wires + copper braid shield). The zip tie holds the cable itself, there is no ...
+1 CAT5 and 6 work absolutely fine for RS485 until the wires break, which will happen eventually if vibration is present or someone opens the panel ...
Heat of vaporization of water is 2.25 MJ/kg (0.625 kWh/kg), this is the amount of heat that must be removed to condense 1kg (or 1l) of water. Dehumidi...
It's a seasonal fruit, like tomatoes lol I bought 2x mobile 4kW units used last February for 200€ each. Dehumidifier is likely to be underpower...
These are identical to mobile aircon units (or US style window aircons) you get a compressor and two refrigerant/air heat exchangers in one box. Dra...
Well deserved! 👌 55°C to the rads is really high, shouldn't be that high if they are oversized. Assuming the heat loss is correct, this shou...
OK Power (Watts) = Flow (in l/s) * Heat capacity of water (4180 J/°C/L) * DeltaT (in °C) Flow (in l/s) = Power (Watts) /( DeltaT (in °C) * Heat ca...
Heat capacity of water is 4180 J/(°C.liter), therefore 1kW = 0.24 °C.liter/s Assuming inlet water temperature 20°C outlet 65°C deltaT 45°C, 1kW cool...
Above dew point cooling is mostly useless. For actual air conditioning you need both cooling and dehumidification which can only be achieved with belo...