Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

Batpred
Batpred
@batpred
Member
Noble Member
Joined: Jan 3, 2025
Last seen: Aug 20, 2026
Topics: 11 / Replies: 1103
Reply
RE: Heresy? or pragmatic engineering? - a suggestion for the a segment of the 'failed boiler/distress purchase' market'

@jamespa I am all for pre engineering… Would I be dreaming that mcs/bus have a service agreement with response times? That is all i can think cou...

3 months ago
Reply
RE: Heresy? or pragmatic engineering? - a suggestion for the a segment of the 'failed boiler/distress purchase' market'

Thanks for sharing, ours is looking fairly different. But your compact summary of the process sounds great, will try to use for ours Before any r...

3 months ago
Reply
RE: Heresy? or pragmatic engineering? - a suggestion for the a segment of the 'failed boiler/distress purchase' market'

As someone that has leveraged and invested based on the current UK system of not paying for capacity, justifying it based on planned usage of an EV, b...

3 months ago
Reply
RE: Failed Heat Pump Install: IWA Claim Rejected

Many of the estimates we received mention IWA and RECC. I try to not read much into it. As @jamespa says, an installer is not expected to be able to e...

3 months ago
Reply
RE: Heresy? or pragmatic engineering? - a suggestion for the a segment of the 'failed boiler/distress purchase' market'

Thanks. I am struggling to reconcile net0 with policymakers settling for reactive action from the DNOs. Can anything else but preemptive work from the...

3 months ago
Reply
RE: Air to Air Heat Pumps

@etchedpixels I understand you are running air/air on it, so how many units do you have and how many rooms do not have one? Otherwise people readin...

3 months ago
Reply
RE: Heresy? or pragmatic engineering? - a suggestion for the a segment of the 'failed boiler/distress purchase' market'

Good point, again, renewables seem to be treated as special as if there was no net0 target..  

3 months ago
Reply
RE: Heresy? or pragmatic engineering? - a suggestion for the a segment of the 'failed boiler/distress purchase' market'

Thanks for sharing. Treating a domestic heatpump (that will often be below 16A, which as 3.7kW means the heatpump would deliver well over 10kW of h...

3 months ago
Reply
RE: Air to Air Heat Pumps

Difficult to estimate in your case. No concerns with the extreme case of one wall/ceiling unit per room. But without seeing thermal conductivity data ...

3 months ago
Reply
RE: Heresy? or pragmatic engineering? - a suggestion for the a segment of the 'failed boiler/distress purchase' market'

I may understand a delay, but a refusal seems plain wrong. Even if there were very restrictive conditions of that supply to start with. Like a 60A fus...

3 months ago
Reply
RE: Air to Air Heat Pumps

I found some in this report from the Building Research Establishment (BRE) group. It supports the view that vast majority have internal solid walls:...

3 months ago
Reply
RE: Air to Air Heat Pumps

That'd be a great thing, if free! My view is that it could become the goal of a new properly trained EPC assessor. But talking practically, I wo...