Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

Travellingwave
@travellingwave
Member
Trusted Member
Joined: Jan 4, 2023
Last seen: Apr 1, 2026
Topics: 2 / Replies: 51
Reply
RE: Heat Pump Books For Beginners – The Ultimate Guide to Heat Pumps, Bodge Buster & From Zero To Heat Pump Hero

@editor Hi Mars Just reading the ultimate heatpump guide - which looks to be a good general introduction for home owners to heatpumps. I apolog...

2 months ago
Reply
RE: Struggling to get CoP above 3 with 6 kw Ecodan ASHP

And a picture of cylinder and surrounding pipe work would help.  

2 months ago
Reply
RE: Struggling to get CoP above 3 with 6 kw Ecodan ASHP

Could do to know what control mode you are using - weather comp or Auto adapt - from your trend looks like you are using weather comp but I’m not too ...

2 months ago
Reply
RE: Struggling to get CoP above 3 with 6 kw Ecodan ASHP

I looked at the trend in the link for booster - I see the booster on flag set but don’t see any corresponding rise in flow temp gets- makes me think y...

2 months ago
Reply
RE: Struggling to get CoP above 3 with 6 kw Ecodan ASHP

Some of this stuff is getting quite technical so let me know if not clear. From memory disabling booster requires changing DIP switch settings insid...

2 months ago
Reply
RE: Struggling to get CoP above 3 with 6 kw Ecodan ASHP

Ref stopping and needing booster to get back up to temp - that sounds like something not set up right. Personally I would disable any booster heater a...

2 months ago
Reply
RE: Struggling to get CoP above 3 with 6 kw Ecodan ASHP

By the way don’t leave it in fixed temp mode - very inefficient - just use it for balancing.

2 months ago
Reply
RE: Struggling to get CoP above 3 with 6 kw Ecodan ASHP

Ref radiator removal- have you checked system pressure - should be about 1.5 bar, might need topping up if you’ve had a rad off.

2 months ago
Reply
RE: Struggling to get CoP above 3 with 6 kw Ecodan ASHP

Did you get any handover pack from your installer? This should state if glycol antifreeze has been added and what concentration.

2 months ago
Reply
RE: Struggling to get CoP above 3 with 6 kw Ecodan ASHP

Also important that UFH is balanced correctly for same reason.

2 months ago
Reply
RE: Struggling to get CoP above 3 with 6 kw Ecodan ASHP

@goodbyegas Well you are warm and your flow temp at 3 Deg outside temp is only 35 degrees so you should be getting pretty decent COP. Hopefully it ...

2 months ago
Reply
RE: Our Experience installing a heat pump into a Grade 2 Listed stone house

@robs I didn’t have the OAT for the full range of data so that’s probably why.

2 months ago