Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

Transparent
Transparent
@transparent
Moderator
Illustrious Member
Joined: Jan 20, 2022
Last seen: Aug 5, 2026
Topics: 16 / Replies: 3334
Reply
RE: Is this a bad installation and is there something wrong with my Samsung heat pump?

I can't find that exclusion clause in the Consumer Rights Act! That's only 5 months ago, anyway.That doesn't sound an abnormally long interval befor...

2 years ago
Reply
RE: Is this a bad installation and is there something wrong with my Samsung heat pump?

The 'banding' can be read as a bar-code which describes how well the defrost cycle is operating 🤔 Was the cavity insulation work ...

2 years ago
Reply
RE: Is this a bad installation and is there something wrong with my Samsung heat pump?

Oh dear, oh dear!Let's take this one point at a time. 1: Are you saying that they drilled 22mm holes vertically through the (suspended) concrete...

2 years ago
Reply
RE: Smart meter installation – seamless or a potential nightmare?

There are a great many layers in the questions you're posing here, Ian.Allow me to first give some clarifications.We can then better understand the is...

2 years ago
Reply
RE: Say hello and introduce yourself

You might wish to see what I wrote this morning about 'handover' on a topic about Bad Installation instigated by another new member of this forum. A...

2 years ago
Reply
RE: Is this a bad installation? Is there something wrong with my heat pump?

No, not good, @david999 😣 Your heat pump works by keeping a 5°C differential between the Leaving Water Temperature (LWT) and the Return Wat...

2 years ago
Reply
RE: Is this a bad installation? Is there something wrong with my heat pump?

Whilst everyone else is discussing the ice, may I comment on the pipework? The standard of the insulation and the way it is routed through the wall ...

2 years ago
Reply
RE: PV inverters seem to interact

Well that's a relief in one sense @geo3geo in that you now have 2 operational inverters, but without the mains trip opening. The less-than-welcome ...

2 years ago
Reply
RE: Retrofitting UFH with a heat pump already installed

This comment is from practical experience, rather than from being being a trained professional: The relative length of each UFH pipe loop does matte...

2 years ago
Reply
RE: Why Your MCS-Certified Installer Might Not Be As Competent As You Think

I think you're on the right track @jamespaThe Competent Persons Scheme is already being promoted by MCS as a quick way to get more HP installers 'out ...

2 years ago
Reply
RE: Why Your MCS-Certified Installer Might Not Be As Competent As You Think

Ah.... Should I point out that the Competent Person Scheme isn't anything to do with MCS.It's actually a long-standing provision within Building Reg...

2 years ago
Reply
RE: Why Your MCS-Certified Installer Might Not Be As Competent As You Think

Isn't it now the case that the government offers to pay £500 of those MCS fees?See this announcement. DESNZ believe that's the solution to overcom...

2 years ago