Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering youāll be able to ask questions, join discussions, follow topics youāre interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Sep 9, 2026
I think @alfapat needs to start labelling cables where they enter the controller box. The outer sheath of mains cables can be written on with pencil...
So where are the connections for the "Booster Heater"? I don't see any thick wires arriving at that point on the board. Is that terminal block abs...
The circuit diagram doesn't match the connection styles/positions on the circuit board. I'm particularly anxious about the thin white wires which mi...
It might be a pipe bracket transferring vibration into a floorboard. Simply touching the bracket with fingers would cause the noise to change. Onc...
Oh dear. So that left you telling the electrician where to stuff it! 😉 For comparison, here's a photo showing one of the (several) te...
Keep asking these questions @ajbevster ... and don't worry if you make an incorrect statementor arrive at a wrong conclusion. Everything you're po...
They are required to commission the system so as to use as little 'fuel' (energy) as reasonably possible. They are also required to instruct the hom...
Apart from the naff electrical tape, what is it about this thermostat which you believe is 'incorrect' @ajbevster Is it still picking up a portion...
@ajbevster - look back at the diagram I posted here a couple of pages ago If the heat pump is getting incorrect data on DHW temperature, how ...
How clear was the issue made to you when you mentioned having a shower pump? Is it just the DHW system which is unpressurized? What about the wate...
- 27 Forums
- 2,761 Topics
- 65 K Posts
- 1,966 Online
- 7,168 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Adventures in heat loss calculations
@cathoderay I'm pleased to see that your cleaned up ...
By Rob of York , 26 minutes ago
-
I bought it, read it, enjoyed it. Despite my earlier c...
By JamesPa , 2 hours ago
-
RE: Tell us about your Solar (PV) setup
Our PV set-up has moved over time. Warning this is a sh...
By Judith , 15 hours ago
-
RE: Where heat loss surveys seem to go against practical reality
@cathoderay @jamespa I've managed to get some nice re...
By Rob of York , 22 hours ago
-
RE: 7kW EV Charger Options Advice
Doh, not sure that I was thinking straight there, less ...
By Rusty , 1 day ago
-
RE: Problems with sizing a replacement for a Viessmann Vitocal 200-S
Iām really liking reading through this thread and the r...
By Judith , 1 day ago
-
Thank you @trebor12345
By rgabor , 1 day ago
-
Panasonic Free Multi Z and Etherea Internal units.
My prospective installers have suggested the Panasonic ...
By Toodles , 2 days ago
-
RE: Next steps on my ASHP journey: Radiators and Pipework
Great. You just need to find a way of cranking up your...
By JamesPa , 2 days ago
-
RE: Heat Pumps Without Grants: Would You Have Installed One & Will You Now?
We had two heat pumps installed without Govt funding. H...
By Rob of York , 2 days ago
-
My Adapt is finally installed and running! Almost a yea...
By tomasmcguinness , 2 days ago
-
-
RE: Being screwed over by Volkswagen Audi Group
Thanks, @batpred. That integration is the one I have in...
By Majordennisbloodnok , 5 days ago
-
RE: How Accurate Is My DIY Heat Loss Calculation?
@batpred I suspect it will be more this year. I had 9 ...
By AndrewJ , 5 days ago