What can you tell from a data sheet? One difference I can see is 5 year warranty vs powerwall 10 year. Good to see new developments hitting the ma...
Just a quick update - carried on monitoring the powerwall in tbc mode Last night it did not charge at all - first time I've seen that behaviour. S...
@toodles Re your earth bonding. I think the answer is in @transparent’s first reply. Leave it in place.
@transparent The diagram in the article isn't saying the earthing arrangement is always TN-S, I think it's saying the earthing arrangement becomes TN-...
Only those that have batteries capable of operating when the grid is down For sure I have an earth stake - added as part of the Powerwall battery...
We had a solaredge diverter as part of our PV system - it worked well. When we had Powerwall installed a couple of years later the diverter and the ...
Apologies to @toodles - thread has been well and truly hijacked. will try not to do it again
Maybe I have found a spoiler! I’m thinking the isolator in the neutral allows the system to be safely switched to island mode and back again. Onc...
@walkers-heatpump setting 19.5C as target temperature would keep it closer to 20 on average. Yes could go over half a degree but shouldn’t go under by...
@transparent Thanks for the detailed explanation. I looked into EV chargepoint earthing a couple of years ago when ours was installed. At the time t...
Thanks for the background @Transparent But they clearly do. To be honest I can see little difference between an earth spike and earth bonding t...
Just a bit more re powerwall earthing… The powerwall gateway includes a breaker to disconnect house live and neutral from incoming when there is a p...
- 25 Forums
- 1,513 Topics
- 31.8 K Posts
- 26 Online
- 1,283 Members
Join Us!
Latest Posts
-
RE: Additional Battery v Wind Turbine v Ripple
I should add, being an investment, the value of your in...
By Old_Scientist , 2 hours ago
-
RE: Ecodan - flow rates, sensors, settings
Achieving an accurate flow measurement is probably the ...
By Derek M , 5 hours ago
-
RE: Ecodan ASHP - How to optimise my set up?
Again, thank you for another thorough post, @derek-m - ...
By rhh2348 , 7 hours ago
-
RE: Delivering a smart and secure electricity system: government consultation
@Transparent.Now that I am represented by a new MP I th...
By IanMK13 , 9 hours ago
-
RE: Vaillant aroTHERM plus not level or flat - what base is best under an external unit?
Similar thread here
By Johnmo , 10 hours ago
-
RE: VDI 2035 heating water specification
Been looking and it seems a good little project. Ever...
By Johnmo , 1 day ago
-
RE: Do I accept an ASHP and Solar Panel retrofit under the HUG 2 scheme?
Will do. I'm currently waiting for another survey / vis...
By dssr , 1 day ago
-
The company that did the borehole were expecting us to ...
By Johnmo , 1 day ago
-
-
RE: The Misquote That Ruined the Heating Industry
@abernyte manufacturer training is pretty average. They...
By Mars , 2 days ago
-
-
RE: ECO4 Scheme and EPC ratings
@mellow Thanks. Given there is a scheme requirement to ...
By Old_Scientist , 3 days ago
-
RE: Do I just go with the lowest quote for my heat pump?
@jancold To me its a no-brainer then, a max 40C flow te...
By bontwoody , 3 days ago
-
-
RE: Heat Pump Books Beginners – Bodge Buster & From Zero To Heat Pump Hero
@editor Presumably he had some good weather Compensatio...
By Toodles , 4 days ago
-
RE: New Vaillant 7kW aroTherm ASHP or oil boiler dilemma/decision??
Storage capacity really is dependent on storage tempera...
By Johnmo , 4 days ago
-
RE: HP Cycling, Expected or Undesirable
Just a little update. I ordered a longer shielded twin ...
By bontwoody , 4 days ago
-
RE: Domestic hot water timer doing crazy things on my Grant Aerona3 10kW air source heat pump
Thanks @allyfish for the pics and info. Spoke to the in...
By Mellow , 4 days ago
-
RE: Aira Heat Pump: Stylish Scandinavian Heating
It's been a busy day for calls and emails from Aira. I ...
By MikeH , 4 days ago
-
RE: Heat Pump Servicing & Maintenance – Good Value or Rip-Off?
Hmm. A bit of a nuanced answer, methinks. As I've alr...
By Majordennisbloodnok , 4 days ago
Latest Topics
-
Ecodan - flow rates, sensors, settings
By rhh2348 8 hours ago
-
Replacing mains water with well water
By Johnmo 2 days ago
-
Additional Battery v Wind Turbine v Ripple
By bontwoody 2 days ago
-
By jamespipe 3 days ago
-
VDI 2035 heating water specification
By Johnmo 3 days ago
-
Do I just go with the lowest quote for my heat pump?
By Jancold 5 days ago
-
The Misquote That Ruined the Heating Industry
By Alec Morrow 5 days ago
-
Battery Storage Wiring Gauge Question
By Puff 6 days ago