I would contact your home insurance company they would normally cover this with their track and track service I would have thought. With 400 ltrs a d...
@derek-m The original heat loss had a design temperature of 50c based on -2.2c external temp and 21c desired internal temp
From the heat loss survey it looks like upstairs has a heat loss of 5.69KW. I've also been told that some heat loss calculations are overly conservat...
@william1066 Grant engineer said the flow rate would be lower with DHW because it's heating to a higher temperature unlike the heating circuit
Ok thanks for this I think it's becoming clearer to me what needs to be done from all of your suggestions. Maybe this is going to be a bigger job tha...
@heacol thanks for all your responses. The problem I have is when the Grant engineer came he disconnected the HP from the system and connected his fl...
So the recommendations were coming from a heat geek installer who I would have expected to know about system design and his suggestion to use 35mm was...
Quick update - I had an heating engineer take a visit to our place and has suggested the following : - Change the 28mm primary heat pump piping to 3...
This is what I found behind the reason for installing a combined volumiser/low loss header -
@shapingstuff a secondary circulating pump will reduce the temp in your cylinder quite quickly and will be expensive to run if it's on all the time. ...
@bretix It was actually part of the RHI scheme so I got a rebate back for installing the metering and monitoring package - a bit of a no brainer for m...
@allyfish Interesting would be a good option as a backup should the ASHP were to fail and we needed at least some minimal heating in the colder months
- 26 Forums
- 2,289 Topics
- 51.4 K Posts
- 238 Online
- 5,949 Members
Join Us!
Podcast Picks
Latest Posts
-
RE: Octopus Cosy Heat Pump Owners & Discussion Thread
People have to get used to the fact that, while running...
By JamesPa , 10 minutes ago
-
RE: Heat Pumps Without Grants: Would You Have Installed One & Will You Now?
I tend to agree. Presumably this is why since 2011 the...
By JamesPa , 19 minutes ago
-
RE: DHW heat loss through pumps.
Exactly. It strikes me that grey water recovery might...
By JamesPa , 22 minutes ago
-
RE: Electricity price predictions
We live in a democracy on a crowded island so everyone ...
By JamesPa , 36 minutes ago
-
RE: Renewables & Heat Pumps in the News
I bought a handful of system in my last job, commercial...
By JamesPa , 44 minutes ago
-
RE: Do Heat Pumps need to start up at Full Power?
@toodles That certainly doesn't look optimal, does it? ...
By Steelbadger , 10 hours ago
-
RE: Grant 13kW Aerona3 - issues getting zones to temp
And the saga continues… So today a Senior Grant Engin...
By Crimson , 15 hours ago
-
RE: Installer Fitted 9kW Instead of 11kW Heat Pump and Changed MCS Paperwork - What do I do?
@jamespa Yes, the OAT sensor is situated on the back pa...
By Toodles , 17 hours ago
-
RE: Ecodan ASHP Low COP and Unstable Compressor Frequency
Just to clarify, returning water from UFH is colder tha...
By lukewarmbath , 18 hours ago
-
RE: 10kw heat pump run in 24*7 data?
A different heat pump (Midea 14kW) but a stark reminder...
By cathodeRay , 18 hours ago
-
From what I see, the work to upgrade the cable, etc all...
By Batpred , 18 hours ago
-
RE: Confusion over Octopus Tariffs
That's sounds great. I have no ASHP, but 15kwh storage....
By Batpred , 19 hours ago
-
RE: Solis S6-EH1P8K-L-PLUS – Why I Chose It and What I’ve Learned So Far
Locked environments are difficult to manage, it also me...
By Batpred , 19 hours ago
-
RE: Has anyone seen this problem before? Huge anticycling times
Hi all, I had a 15kw installed 3 weeks ago. The past we...
By jamesh , 24 hours ago
-
Adia Therma - 'autopilot for heat pumps'
Thought I'd pop this one in here as the Adia proposal a...
By seatonian , 2 days ago
-
RE: Mitsubishi Ecodan R290 10kW performance
Don't know answer to final question. Your contract p...
By JamesPa , 2 days ago
-
RE: New Fogstar 15.5kWh upright solution
Ah, it seems PACE BMS are easy to source on AliExpress,...
By Batpred , 2 days ago
-
RE: Vaillant water pressure gauge vs Analogue gauge
@jamespa Agreed I don't feel concerned about this, espe...
By jeegnesh , 2 days ago
-
RE: Gov wants to alter our FIT contracts from rpi to cpi
The consultation is just part of the normal process for...
By Jeff , 2 days ago