Activity
 
Notifications
Clear all
sjn
sjn
@sjn
Member
Trusted Member
1003 kWhs
Joined: Mar 25, 2024
Last seen: Feb 9, 2025
Topics: 1 / Replies: 22
Reply
RE: Is this a bad installation and is there something wrong with my Samsung heat pump?

@transparent the TB-C F1 & F2 screw terminals with the screened twisted-pair are the RS-485 link to the Outdoor Unit. I agree with your comments...

9 months ago
Reply
RE: Is this a bad installation and is there something wrong with my Samsung heat pump?

@david999 The blue and brown wires at the top right are connected to TB-C F3 & F4 on the controller PCB. I'm sure this is the RS-485 communic...

9 months ago
Reply
RE: Noise problems with newly installed Samsung 8kW ASHP

@elton that's interesting about the tonality of the noise. Certainly when the noise from our pump is most obtrusive it is a very harsh, complex sound ...

9 months ago
Reply
RE: Noise problems with newly installed Samsung 8kW ASHP

@lokisam it is good that you have been able to visit other sites to compare the noise with your pump. I haven't found any other Samsung installations ...

9 months ago
Reply
RE: Noise problems with newly installed Samsung 8kW ASHP

Thanks @allyfish - yes dry lining on a timber frame. I'll get the clips changed to insulated/cushioned ones to see if that reduces some of the noise...

9 months ago
Reply
RE: Noise problems with newly installed Samsung 8kW ASHP

@lokisam, I also have what feels like a very noisy 8kW Samsung ASHP. The noise gets all through the house (new build, single story, 2 bedroom, underfl...

9 months ago
Reply
RE: Samsung ASHP scheduling help

Hi @morh. Excellent find, thank you for sharing. I was about to start looking at how to route a signal cable to my external unit before buying a Mod...

10 months ago
Reply
RE: Is this a bad installation and is there something wrong with my Samsung heat pump?

@david999 the OAT sensor on the back of my 8kW unit looks the same as yours. I think the actual sensor is towards the open end of the pipe and the cab...

11 months ago
Reply
RE: Is this a bad installation and is there something wrong with my Samsung heat pump?

Here is a picture of my Samsung Gen 6 8kW yesterday evening. The outside air temperature was 3.5C, the relative humidity was around 90%, and the ASHP ...

11 months ago
Reply
RE: Say hello and introduce yourself

Thanks @transparent, I'll have a look at that.

11 months ago
Reply
RE: Say hello and introduce yourself

Hi, I'm Stuart. I live by Loch Ewe in the Northwest Highlands of Scotland. We have a Samsung Gen 6 8kW ASHP with a Joule Smartplumb Unvented Cylinde...

11 months ago
Page 2 / 2
Share:

Join Us!

Heat Pump Dramas?

Thinking about installing a heat pump? Or already have one but it’s not performing as it should? Rob is here to help!

Pre-Installation Planning
Post-Installation Troubleshooting
Performance Optimisation

👉 Book a one-to-one consultation now.

Latest Posts

x  Powerful Protection for WordPress, from Shield Security
This Site Is Protected By
Shield Security