Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Jan 16, 2026
@editor apart from the question of noise, as the argument is that propane is heavier than air, I see no reason not to have the heat pump under a windo...
My view in this is to weigh the risk to the reward. There’s no actual regulation I know of that limits siting of R290 plant. But, and this is the...
@adamk Tesla is a great option, it’s also one we install a lot of. Again, not perfect as there are limitations in scalability and control can be ve...
It’s a really simple answer, GivEnergy. Installers and the market place got really used to the bargain that was GivEnergy. It’s all gone a bit...
ok. So for most heat pump clients we recommend a minimum of 20kWh in combination with either a single long low tariff or one with multiple low rate...
It would be good to understand what you are trying to achieve. By that I mean, what are the off grid loads in kW, estimated run time required in isla...
@heat-pump-newbie It’s not a requirement in the handover pack but it should definitely be available if requested
This is determined by a wind load calculation. the calculation will tell you the total uplift in Nm. The manufacturer will have a specification ...
from that description it would seem to be badly terminated or failing connection at the MCB. It’s relatively simple to sort out, replace MCB, trim ca...
Hi I install these batteries as well as having a system with two 9.5kWh packs. there is an ongoing issue with SOC drop off and I expect this is c...
You can check the ENA database and it will tell you what the max demand is as well as if it is connect and notify or not. easiest solution is to s...
@heat-pump-newbie I would want it properly checked out. If there is a refrigerant leak it’s rarely a good thing. You could be very lucky and it’s al...
- 27 Forums
- 2,811 Topics
- 66.5 K Posts
- 2,663 Online
- 7,217 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Why don't people choose heat pumps?
It's swings and roundabouts - during off-peak periods t...
By Temperature_Gradient , 30 minutes ago
-
RE: The Changing Jet Stream Could Challenge UK Air Source Heat Pumps
... And that's being generous! I'll tell you a littl...
By SusannaSaunders , 7 hours ago
-
RE: Adding data centre electricity costs to domestic energy bills?
never ceases to amaze me.. Keeping steel works going ...
By Batpred , 8 hours ago
-
RE: Electricity price predictions
great session Reminds me why some politicians can be ha...
By Batpred , 8 hours ago
-
RE: Boiler Upgrade Scheme funding reduced by circa £750 million in 2026 budget
Absolutely agree. The massive Hager CU my vaillant requ...
By Batpred , 8 hours ago
-
RE: How much of your renewable and home setup would still work if the internet went down?
absolutely agree. even if many providers see that extra...
By Batpred , 8 hours ago
-
RE: Octopussy cosy 6 experience
People who have a Cosy appear generally to be happy wit...
By JamesPa , 12 hours ago
-
I thought the cr*p came first and the biofuel came afte...
By Majordennisbloodnok , 15 hours ago
-
RE: Aerotherm and weather compensation
@jamespa I replied yesterday with detailed readings whi...
By DavidB , 2 days ago
-
RE: Marvel Heating liquidation
@editor This is an important point. each winter, you...
By davidnolan22 , 3 days ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
Very nice. we’ve been super soggy here, but rather m...
By Papahuhu , 4 days ago
-
RE: DIY powerflushing tutorial
Interesting! I toyed with the idea too. But I installed...
By bobflux , 4 days ago
-
RE: 15kw pump for 225m2 1990's house - over kill?
@seaviews Agree with the others on sequence: loft first...
By mk1234 , 4 days ago
-
RE: Vaillant ecoTEC Plus - Flow Temp and Set Up
Heating been on for 4 weeks now, continuous. It's 6C o...
By trebor12345 , 5 days ago