Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

Old_Scientist
@old_scientist
Member
Honorable Member
Joined: Jun 16, 2024
Last seen: Sep 18, 2026
Topics: 9 / Replies: 550
Reply
RE: Why One Strike on Iran’s Oil Infrastructure Undermines Every Heat Pump and Solar Array in Britain

Same here - I record the price of oil on the 1st of each month in my spreadsheet and work out what my break even price for electricity would be given ...

6 months ago
Reply
RE: Fitting a volumiser to an existing system

All very reasonable. During 2 winter's of usage, I only recall 1 defrost cycle occurring during the DHW cycle, probably a result of always trying to r...

6 months ago
Reply
RE: Fitting a volumiser to an existing system

@jamespa Sorry, I've checked and am unable to find a system schematic showing a volumiser in any of my Samsung documentation (I thought it did). The...

6 months ago
Reply
RE: Fitting a volumiser to an existing system

Whilst I generally agree with the above, it can be manufacturer specific. For example, my Samsung heat pump will take heat from whichever cycle is a...

6 months ago
Reply
RE: Why One Strike on Iran’s Oil Infrastructure Undermines Every Heat Pump and Solar Array in Britain

@morgan A friend of ours told us they placed an order with Boiler Juice just before the conflict and Boiler Juice cancelled the order a couple days la...

6 months ago
Reply
RE: Other than heat loss, radiator sizing, ASHP sizing, what else goes into a design and how important is it?

Indeed. My point was that if you design for a flow temp of 50C at -3C based on a 10kW heat loss, and in reality the heat loss is more like 7kW then yo...

6 months ago
Reply
RE: Other than heat loss, radiator sizing, ASHP sizing, what else goes into a design and how important is it?

@petch just wondering how your averaged heat loss survey data compares to actual usage data. Is your existing boiler gas, and if so do you have access...

7 months ago
Reply
RE: Other than heat loss, radiator sizing, ASHP sizing, what else goes into a design and how important is it?

@petch Yes, if the flow and return pipes immediately split into 22mm runs for upstairs and downstairs, then each branch should theoretically be able t...

7 months ago
Reply
RE: Other than heat loss, radiator sizing, ASHP sizing, what else goes into a design and how important is it?

All great advice 👍 Going back to radiators and pipework sizing, once you have a heat loss calculation, broken down room by room, you can st...

7 months ago
Reply
RE: Heat Pump vs New Gas Boiler for Inherited House - Worth the Extra Cost?

Hi @fretless6 Mike, I have experience with Taggas (Retford), as they installed my system (a 12kW Samsung unit) on an ECO4 grant. The design proces...

7 months ago
Reply
RE: Axle - £1 per kWh!

@toodles I watched with interest too. My first thoughts was that it would be a good addition to run alongside/in addition to Cosy in winter (I still...

7 months ago
Reply
RE: Domestic wind turbines

Agreed. When I first looked into domestic wind, my initial impressions were there are easier ways of generating 2.5kW of intermittent renewable power ...

7 months ago