Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Sep 16, 2026
Indeed not, I think, unless you take measurements regularly, it reduces to a 'sense check' in this case based on annual consumption or the like. Stil...
A big part of the problem, at least on this forum, seems to be that we dont know what the problem is! Im beginning to doubt that its known nationally...
If your heat loss is only 4kW and the pipes leaving the boiler are 22mm then its fairly unlikely you need any upgrades; 15mm is good for 3kW at 1m/s f...
Can I just add another 'vote' in favour of measuring heat loss using consumption if you can. Here is the data (from my gas boiler) which I used to si...
@transparent Thats really helpful Can I summarise what I 'take away' to test if Ive got it rioght Thats key then. You have said that t...
No you arent, because you dont need any, and furthermore shouldn't have any other than the controller that comes with the heat pump. Third party heat...
Can you link them to Home Assistant so they can be intelligent?
I have often thought the same. In Italy (I am told) there is an element of pricing which is dependent on the supply capacity (basically you pay more ...
As I mentioned earlier most radiators have a power output proportional to (Trad-Troom)^1.3. There is a brand of aluminium radiators (Eskimo) that cla...
@transparent Im impressed by all your work on this. Triggered by the various comments Im now trying to make sure I understand the actual problem(s)...
I get the scientific argument however I would ask what is any government supposed to do given the real political pressures? Nodal pricing was droppe...
This is absolutely standard for any sealed pressurised system (ie any system without a gravity fed tank usually in the loft). This is true whether bo...
- 27 Forums
- 2,768 Topics
- 65.2 K Posts
- 1,554 Online
- 7,172 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Why are ASHP installs so expensive?
@batpred I take your point and, perhaps, your experienc...
By ian33a , 10 hours ago
-
RE: Who's your electricity provider and what's your tariff?
@batpred When the raw material input has increased in c...
By Papahuhu , 1 day ago
-
We kept ours and Heat Geek would have been in touch if ...
By Batpred , 1 day ago
-
RE: Missing flow temperature in Heat Geek proposal
The Heat geek contract had various get-out clauses with...
By Batpred , 2 days ago
-
RE: Starting Our Heat Pump Journey: 1962 build 3 bed detached house
@ian-s I would encourage you to have a conversation ...
By Rob of York , 2 days ago
-
RE: Is it the house or the equipment?
Thanks @jamespa The last hard to fix draughts in the...
By springswood , 2 days ago
-
RE: Vaillant Arotherm – Using Heating
@l8again Mine is typically using 11w including the i...
By Batpred , 2 days ago
-
RE: Next steps on my ASHP journey: Radiators and Pipework
If you have a flowmeter and two temperature probes, the...
By bobflux , 2 days ago
-
RE: Siting of the external sensor on a heatpump
@jamespa Absolutely. Even if the same mistake was mad...
By Batpred , 3 days ago
-
-
RE: Recommendations in Ely (Cambs) area for Full setup checks on Nibe HP setup for House.
In fairness all heating has cost a lot to run in recent...
By JamesPa , 4 days ago
-
RE: Navigating the World of Refrigerants In Heat Pumps: A Guide for Homeowners
Indeed we are invvestigating AC at present and are havi...
By Toodles , 5 days ago
-
RE: Daikin ESPAltherma and Home Assistant installation
It's laziness lol The PV system is very chatty, meter...
By bobflux , 5 days ago
-
RE: Problems with sizing a replacement for a Viessmann Vitocal 200-S
R (The R Project for Statistical Computing, I use it wi...
By cathodeRay , 6 days ago