Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

JamesPa
JamesPa
@jamespa
Moderator
Illustrious Member
Joined: Apr 3, 2023
Last seen: Aug 25, 2026
Topics: 27 / Replies: 5282
Reply
RE: ASHP decision: Should I or shouldn't I?

I find that with weather forecasts you need to be careful how you 'read' them. For example a '30% probability of rain' could be because you are edge ...

3 years ago
Reply
RE: My horrific Samsung heat pump installation and experience

"Can you define "Short Cycling"? Is this short Cycling , acceptable , during April , during the prime Short cycling month of April?" Unfortuna...

3 years ago
Reply
RE: My horrific Samsung heat pump installation and experience

@derek-m Thanks, that would be much appreciated!

3 years ago
Reply
RE: My horrific Samsung heat pump installation and experience

There are various online calculators for flow and pressure. Temperature loss in pipes should be either negligible or within the insulated envelope o...

3 years ago
Reply
RE: ASHP decision: Should I or shouldn't I?

Personally I both play with models (railways) and work with them. Experiment and theory complement each other. and modelling is not a modern obsessi...

3 years ago
Reply
RE: My horrific Samsung heat pump installation and experience

Yes but this reduces the remaining voltage (pump head) available not the current (flow). And friction losses don't cause a temperature drop they cau...

3 years ago
Reply
RE: My horrific Samsung heat pump installation and experience

Sorry but the analogy doesn't work. Pipes convey heat from one end to another according to your equation, they don't dissipate it according to this e...

3 years ago
Reply
RE: My horrific Samsung heat pump installation and experience

In the analogy you are trying to draw, the voltage is the pump head (pressure) not the water temperature. The flow rate is the current and the impeda...

3 years ago
Reply
RE: ASHP decision: Should I or shouldn't I?

If you haven't already you might want to re-read my earlier post which has a link to a worked example of spatial zoning and draws some analogies betw...

3 years ago
Reply
RE: My horrific Samsung heat pump installation and experience

Are you certain of 6.5C, Have you checked the actual temperature at the output of the Samsung?. If so, are the pipes insulated and are the flow rates...

3 years ago
Reply
RE: My horrific Samsung heat pump installation and experience

Im not sure how helpful the analogy is. The key point is that the buffer is (at DC) most probably a relatively low impedance path compared to the hea...

3 years ago
Reply
RE: My horrific Samsung heat pump installation and experience

Good, we agree then! The problem is to persuade @iantelescope and, more to the point, his installer. My personal theory (based on what @iantele...