I think you probably mean RCDs rather than MCBs. Vaillant, in common with many heat pump manufactures, specify Type B RCDs which, unlike the more ...
You should contact the council and report the unsatisfactory work, requesting them to withold paynent. Without rawlplugs (how do you know) your radia...
Not sure that's what you meant albeit that the industry could do with some comic treatment!
Strange. Very definitely in the UK there are two separate industries namely commercial aircon, who all have f-gas qualifications so can work with re...
Commercial aircon people would normally do this in the UK, I imagine same in Portugal. Does it actually need doing?
Indeed. With a battery its presumably the battery controller that does all the heavy lifting with load optimisation, so I'm not sure Havenwise helps...
Strictly they should be insulated (building regs I believe) to stop them 'leaching' heat from the tank, unless of course you want the heat for somethi...
Delighted to hear this went well. It looks very neat The only comment I would make about the installation is that pipework within 1m of the DHW tan...
Thats presumably heat pump DT, what about radiator DT and, importantly, temp diff between flow from heat pump and flow to rads (ie temp diff across th...
... and incorrect given the wording you quote. I bet they would lose if you challenged it in court or through the ombudsman. As you say It seem...
If it says heating system it should cover you for damage unless there is an exclusion. I would challenge them if they claim otherwise, then keep a re...
Are you sure its not covered by 'central heating system' or such wording. I contacted mine (which also does not mention heat pumps) and they confirme...
- 26 Forums
- 2,228 Topics
- 49.5 K Posts
- 195 Online
- 5,890 Members
Join Us!
Podcast Picks
Latest Posts
-
Samung 16kw 5 months in - Happy with heat and DHW but some questions
Where to start? In brief we are happy with the system...
By DowallyDrifter , 45 minutes ago
-
Question about Heating Pump Operation mode – Ecodan FTC6 v20.06
I have a Mitsubishi Ecodan EHST20D-YM9D with PUHZ-SWM80...
By Johj45 , 57 minutes ago
-
RE: Electricity price predictions
Currently we are a net importer of electricity, and one...
By Jeff , 58 minutes ago
-
RE: How good is the app support for your heat pump?
@batpred you can create bluetooth repeaters from esp32 ...
By Grantmethestrength , 2 hours ago
-
RE: Replacing knackered oil boiler with ASHP - Perthshire
@jamespa just confirming that after 5months with the 16...
By DowallyDrifter , 2 hours ago
-
RE: Struggling to get above 3.3 on heating
The first chart in your post above shows average 0.25kW...
By JamesPa , 2 hours ago
-
RE: How to increase DHW water temperature on Samsung Gen 6 Control Panel
Im just in the process of connecting up my mixergy cyli...
By bontwoody , 9 hours ago
-
Unless anyone can tell me differently, there appears to...
By DowallyDrifter , 12 hours ago
-
RE: Should Our Water Circulation Pump Be Configured to Run All The Time?
I run my Vaillant on either expanded mode (either end o...
By JamesPa , 14 hours ago
-
RE: Twin 10kw Grant Aerona Volumiser Tanks using lots of power
@adam Hi just jumped on this thread as I too have 2 10k...
By bretix , 23 hours ago
-
RE: Help me keep the faith with my air source heat pump installation
on a facebook thread someone has comented to the effect...
By AdamK , 23 hours ago
-
-
RE: Samsung Heat Pump – Can't Activate TW2 Pipe Sensor (for Delta T Control)
Wanted to add an update. As I am running HomeAssistan...
By bubuontheweb , 1 day ago
-
RE: Grant 13kW Aerona3 - issues getting zones to temp
You are correct you dont need the second pump if there ...
By JamesPa , 1 day ago
-
RE: New Fogstar 15.5kWh upright solution
From my experience with inverters from different Far Ea...
By Transparent , 1 day ago
-
@bontwoody Thank goodness you are ‘back on-line’ so to ...
By Toodles , 1 day ago
-
RE: Automation options to maximuse efficiency & ToU tariffs
@majordennisbloodnok Seems reasonable. It would be m...
By Batpred , 1 day ago
-
RE: Havenwise App Help & Forum Support – Get the Most from Your Heat Pump
@hcas OK Thanks. Will do.
By bontwoody , 1 day ago
-
RE: What crazy nonsense are inverter limits and why are they imposed?
@transparent Thank you for a very comprehensive, tim...
By Batpred , 1 day ago
-
RE: Isolating the system for a planned power cut
@transparent 😊 I may have lost you there.. I ...
By Batpred , 1 day ago