Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Oct 22, 2026
I am planning on trialling night time 'set forward' to take advantage of cheap rate tarrif. I have no idea if it will work in practice. The challeng...
Thanks for that, I think there is much comfort to be drawn because of: ... with which, based on everything you have told me, I agree. My heat ...
I think that conditions over the last couple of days are about the worst possible - cold but very wet = lots of defrost. I too am interested in what ...
I'm not an ecodan expert but this looks like defrost to me. The give away is that FT goes below RT.. Conditions for defrost are about as bad as they...
I think you are very likely right unfortunately. This is a somewhat surprising conclusion given that the system was presumably designed by Freedom an...
I confess Im a bit mystified. How was the WC curve determined. If it was determined experimentally, then cycling and losses in PHE etc would be, at ...
It claims to use the energy integral as part of the cycling control loop, but is silent about how the defrost control loop works, so I dont know! ...
One might expect (hope) that the heat pump takes this into account in the control circuit, by accumulating differences and overshooting to compensate....
OK, so (assuming Freedom are correct) you actually have two problems. The principal one is that the max pump rate is insufficient, leading to your ou...
All agreed In detail that is true. However its a dead cert that its primary control loop adjusts the compressor frequency and fan speed to a...
- 27 Forums
- 2,799 Topics
- 66.2 K Posts
- 2,907 Online
- 7,206 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Indevolt Batteries UK Support & Info Thread
@dansus yeah, that definitely needs fixing. Good spot. ...
By Mars , 3 hours ago
-
RE: How will removing the standing charge on gas bills benefit heat pumps?
@toodles GIGO always stands! My Cosy 6, as you can...
By Watcher , 7 hours ago
-
RE: How much of your renewable and home setup would still work if the internet went down?
Interestingly we had an internet outage about a month a...
By Rob of York , 13 hours ago
-
RE: Double or Triple Glazed Windows?
Posted by: @singlespeed With 9 years repairing windo...
By Rob of York , 14 hours ago
-
@transparent we’re still running a secure version of PH...
By Mars , 17 hours ago
-
RE: How quickly would you want/expect heat recovery to take from setback?
Much longer than that here. The heating isn't even on. ...
By bobflux , 1 day ago
-
RE: Passiv Smart Thermostat - Help & Forum Support
Obviously the weather is changeable but there's a defin...
By Singlespeed , 1 day ago
-
RE: The Changing Jet Stream Could Challenge UK Air Source Heat Pumps
@rob-of-york I must admit that when we had a Daikin hea...
By Toodles , 1 day ago
-
RE: Forum updates, announcements & issues
Get the Renewable Heating Hub heads-up on WhatsApp. I...
By Mars , 1 day ago
-
RE: Safety study for plug in batteries out to tender - looks like Q3 2027 at best before legal
@editor I pointed out to the one of the Fuse execs that...
By dansus , 1 day ago
-
RE: 15kw pump for 225m2 1990's house - over kill?
@seaviews As well as loft insulation, there are othe...
By Rob of York , 2 days ago
-
RE: BT cuts you off, Plusnet blames Openreach... welcome to “seamless” broadband switching
Both of which (in most cases) use Openreach for the las...
By JamesPa , 2 days ago
-
RE: Renewables & Heat Pumps in the News
Yes, this is a swiss and german standard I believe, Vai...
By Batpred , 2 days ago
-
RE: Octopus Cosy 12 Heat Pump Regret: Incredibly Loud, Poor Heating & Constant Hum - Help!
@editor FWIW my problem was resolved, eventually, after...