Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

JamesPa
JamesPa
@jamespa
Moderator
Illustrious Member
Joined: Apr 3, 2023
Last seen: Aug 20, 2026
Topics: 27 / Replies: 5272
Reply
RE: LG Therma V outdoor temp sensor

The sensor should really be outside in the shade, not inside the unit or in sun. Assuming it's separate (some ashps only have sensors in the air inta...

2 years ago
Reply
RE: Grant 13kW Aerona3 - issues getting zones to temp

@crimson In answer to the question no, unless the lockshield is behaving oddly which will wouldn't rule out. Does turning it back up reduce the te...

2 years ago
Reply
RE: Avoid the Heat Pump Villain: Why Low-Loss Headers and Buffers Can Sabotage Your Heat Pump's Efficiency

Check whether by 'buffer' they mean 2port volumiser (the key feature being 2 port). That's ok. It's typically 20-50l.. Vaillant do put a volumiser ...

2 years ago
Reply
RE: Business case for a battery?

That's fair I agree this is too crude. It needs to be done properly or not at all. There are at least four companies developing various smart c...

2 years ago
Reply
RE: Business case for a battery?

I think most of your criticism of the denz proposal makes sense to me although I can see why turning off heat pumps is attractive. Houses are large s...

2 years ago
Reply
RE: Grant 13kW Aerona3 - issues getting zones to temp

The Grant R290s (if thats what you have) may just be Midea based. If so then you could contact Adia (see my post above). They are looking for test s...

2 years ago
Reply
RE: Grant 13kW Aerona3 - issues getting zones to temp

I think that's a fundamental limitation with weather compensation, and probably why we didn't adopt it (unlike many other countries). Balancing radia...

2 years ago
Reply
RE: Installations in Flats

Permissions and access are the issues. Planning permission will be needed unless it's the first on the building or within the curtilage and ir meets ...

2 years ago
Reply
RE: Grant 13kW Aerona3 - issues getting zones to temp

@crimson As Im sure you know there are various things that stop ASHPs (and boilers) running including but by no means limited to Flow too low (...

2 years ago
Reply
RE: Grant 13kW Aerona3 - issues getting zones to temp

Sorry to hear your problems but it sounds like you are now on the right track. It also sounds like you have learned a lot about heat pumps during your...

2 years ago
Reply
RE: Heat Pump sizing - Further adventures of a boiler owner

There is sometimes quite a good argument for this and many heat pumps do have the capability to drive electric heaters inline. Check actual specs at ...

2 years ago
Reply
RE: Installing a heat pump in a Grade II listed property

In this case it's in the case. There is also conclusive evidence that it reacts to what the heat pump is doing.

2 years ago