Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

JamesPa
JamesPa
@jamespa
Moderator
Illustrious Member
Joined: Apr 3, 2023
Last seen: Oct 21, 2026
Topics: 28 / Replies: 5525
Reply
RE: Looking for some advice – no viable installer/system – I'm stuck

I wouldn't give up. You presumably have cavity walls which either are, or could be, insulated and either double glazing or the potential to fit it. ...

2 years ago
Reply
RE: ASHP & Radiator Sizing - Measuring Heat Loss

Firstly, your method may well work, Im jolly impressed and please continue to post to inform us all! In response to your comment above a) I ob...

2 years ago
Reply
RE: How To Balance Radiators & the Role of the Lockshield Valve: A Homeowner's Guide

OK. 16kW is not compatible with 22mm pipework, and barely compatible with 28mm at a typical design DT across the radiators of 5C/p> That said 16kW...

2 years ago
Reply
RE: How To Balance Radiators & the Role of the Lockshield Valve: A Homeowner's Guide

If you remove the buffer you will also need to remove the secondary pump. Re your concern, it depends. Some further detail will help determine. ...

2 years ago
Reply
RE: ASHP & Radiator Sizing - Measuring Heat Loss

What is your concern triggering the question. I am impressed at trying to determine individual rooms, I was content to determine whole house by meas...

2 years ago
Reply
RE: Octopus design temperatures confusion

No to the first. You can reduce the temperature of the other rooms by adjusting the lockshield valves. You have to do this anyway because radiators ...

2 years ago
Reply
RE: How To Balance Radiators & the Role of the Lockshield Valve: A Homeowner's Guide

Thanks Sadly with a 60cm high tank I think the chances of maintaining stratification (IE a temperature gradient from top to bottom, which is wha...

2 years ago
Reply
RE: Octopus design temperatures confusion

Not exactly. Type 11 = 1 panel, set of fins, type 21 = 2 panels 1 set of fins, type 22 = 2 panels 2 sets of fins. Unfortunately SC could be 11 or 2...

2 years ago
Reply
RE: Octopus design temperatures confusion

I suspect 60dc120 means 60cm high 120cm long double convector. SC single convector. Heat loss same so good, only issue seems to be rad size/flow te...

2 years ago
Reply
RE: Octopus design temperatures confusion

The temperatures you quote are the standard mcs minimum design temperatures. The MCS and grant rules allow them to be raised but not reduced. Try pu...

2 years ago
Reply
RE: How To Balance Radiators & the Role of the Lockshield Valve: A Homeowner's Guide

Sorry I didn't spot the pictures above. Buffer tank looks very squat (which would explain lots). How high is it and what is the vertical distan...

2 years ago
Reply
RE: Vaillant arotherm plus heat pump frost protection

@kentuk It occurs to me, have you got a timed heating schedule and if so what is it. Can you tell me why the indoor temperature was so low in the ...