Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Jan 14, 2025
graham hendra's youtube
in the mode you have been setup with, the samsung stats "superior thermostat control" may not be being used. see most of the settings on page 6 of ...
glad it was an easy fix. sometimes the basics is all that needs checking!
better with the example. Obvious options: - move the measurement points so they are still on the same pipe, but further away from the metal mass of ...
hi mike so on the samsung side B22 is the switched 230v live input for heating. B21 if you want to put the system in cooling mode, remember it can c...
there's no modbus register for the offset. in any case, redzer_irl has just got working, exactly what I wanted to get working (being able to turn th...
@redzer_irl I can't remember what is set for me in 2092 but perhaps its needs both. I have not used the configuration that I referred to in "normal ru...
@redzer_irl if you set FSV 2091 to "not use" you should end up with this (I do) that allows you to directly manually set the target water outlet ...
I did this calibration method with the first few, but they were pretty close to right so I got lazy...depends on how keen you are!
@andehh 53.5 is achievable by the heat pump alone. I have a samsung G6, if I run it in DHW mode, I can get the cylinder to 55 using purely the ASHP. ...
@cathoderay I indeed use what you say. I have £5 ESP wifi boards hiding in corners in various rooms (this is needed to keep the wiring to the sensors ...
@iantelescope like I said, ds18b20's work for me and hundreds of other people, there is umpteen pages on this in energy monitoring forums. I'm just ob...
- 26 Forums
- 2,727 Topics
- 64 K Posts
- 1,587 Online
- 7,131 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
Absolutely. Totally agree. @cathoderay and I, amongst o...
By Majordennisbloodnok , 10 minutes ago
-
RE: Indevolt Batteries UK Support & Info Thread
My UPS (used for my computer and networking equipment) ...
By JamesPa , 48 minutes ago
-
RE: HeatGeek vs Octopus surveys: puzzling disparity - any ideas why?
We selected and bought most of the rads. Most were fit ...
By Batpred , 3 hours ago
-
RE: Cleaning solar panels with a hosepipe
@jamespa, thanks for setting up this offshoot of a disc...
By Majordennisbloodnok , 4 hours ago
-
RE: Missing flow temperature in Heat Geek proposal
I have looked through the documentation again and the o...
By L8Again , 4 hours ago
-
RE: Microgeneration Certification Scheme (MCS)
I suspect this is why HG has massive ventilation losses...
By Batpred , 7 hours ago
-
@trebor12345 If you select the Change Rate Plan button,...
By Toodles , 23 hours ago
-
RE: Jokes and fun posts about heat pumps and renewables
@majordennisbloodnok Well, I can use such terms as HMRC...
By Toodles , 2 days ago
-
RE: Heat Pump Servicing & Maintenance – Good Value or Rip-Off?
I'd picked up that there was a leak coming from around ...
By Sheriff Fatman , 2 days ago
-
RE: Who's your electricity provider and what's your tariff?
Great info. Thank you. Regards Pete
By peterackstraw , 2 days ago
-
-
RE: Samsung heat pump - data cable issue
That's well done. Cable is the correct type (LIYCY = 2x...
By bobflux , 5 days ago
-
RE: Electricity price predictions
I agree, we will find out at the next budget whether th...
By Old_Scientist , 6 days ago
-
RE: Air to air bus grant installer anywhere
The through wall two hole ones have their place (listed...
By EtchedPixels , 6 days ago