Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering youβll be able to ask questions, join discussions, follow topics youβre interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Jan 14, 2025
also its worth saying, the PWM pump is not the enabler to run at low flow temps. That comes from having big enough emitters, properly balanced, etc. ...
@ecobaker mine did not need a firmware change. the PWM worked first time. I am not even sure how you would go about getting a firmware change done. ...
@bontwoody it will run at 35, but only stably if you have enough emitters to balance the min output of the HP. Which in my case with a 16kw gen6 unit...
probably about a grand's worth as well. which could have been not spend during the original install. its not just for laughs that we keep banging on...
@ecobaker you might want to check that the right valves are open and not open when wanted. I suggest drawing a plumbing diagram and a wiring diagram a...
@ecobaker the description of what the system did makes total sense if there was nothing running round the rads. as you have an LLH you need the second...
physics says that if you know what flow rate the existing circulation pump is running at, its power level, and the characteristic curve of the pump (w...
there is one G6 8kw on HPM.org, here , low point seems to be about 2.5kw. The owner of that one might be on this board as well, I can't remember. ...
@ecobaker so... your points, summarised. the guides you need are all here. type MIM-E03CN into the search. the MIM controller manual has all the p...
@editor I did look at 3 phase, it was painful, got quoted 10k just for the DNO piece. and that was for tapping into the phases that's only 5 metres aw...
@jamespa I was wondering if you might say this π . those who've self installed have , generally speaking, installed in such a way that is compliant ...
@ecobaker if its in the airing cupboard it'll be no use, you need to move it to a living space to use it as the stat. Two wire low voltage so easy to ...
- 27 Forums
- 2,761 Topics
- 65 K Posts
- 1,233 Online
- 7,167 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: 7kW EV Charger Options Advice
On the front wall. The meter tails go into a Henley blo...
By Rusty , 24 minutes ago
-
RE: Where heat loss surveys seem to go against practical reality
@cathoderay I think there is a reasonable argument t...
By Rob of York , 25 minutes ago
-
Panasonic Free Multi Z and Etherea Internal units.
My prospective installers have suggested the Panasonic ...
By Toodles , 4 hours ago
-
Hi @jamespa , @trebor12345 ,Thank you both for the repl...
By rgabor , 4 hours ago
-
RE: Next steps on my ASHP journey: Radiators and Pipework
Great. You just need to find a way of cranking up your...
By JamesPa , 6 hours ago
-
RE: Heat Pumps Without Grants: Would You Have Installed One & Will You Now?
We had two heat pumps installed without Govt funding. H...
By Rob of York , 6 hours ago
-
My Adapt is finally installed and running! Almost a yea...
By tomasmcguinness , 13 hours ago
-
-
RE: Being screwed over by Volkswagen Audi Group
Thanks, @batpred. That integration is the one I have in...
By Majordennisbloodnok , 3 days ago
-
RE: How Accurate Is My DIY Heat Loss Calculation?
@batpred I suspect it will be more this year. I had 9 ...
By AndrewJ , 3 days ago
-
RE: Surface mount or bury primaries for heat pump installation?
@jamespa It's rusting π
By tomasmcguinness , 3 days ago
-
RE: Glass lined Cylinder for private water supply
Thank you, once again, for your replies. Yes...
By ian33a , 3 days ago
-
Itβs been out a few days and Amazon has already attache...
By Mars , 3 days ago
-
RE: Missing flow temperature in Heat Geek proposal
Yes, and this is another point I agree. We did find a f...
By Batpred , 3 days ago
-
RE: Problems with sizing a replacement for a Viessmann Vitocal 200-S
A very good point. In effect, the DHW pipework is an em...
By cathodeRay , 4 days ago