@markc The installers put buffer tanks in to stop low flow errors occurring with their badly designed heating systems. It covers their inadequacies, a...
@derek-m You are correct for old fixed compressor units. Most manufacturers recommend 10 litres per KW from flowing volume for a heat pump. Most new i...
@markc That valve you have there is a low flow high-temperature valve, you are throttling your system, effectively it cannot breathe. You need to chan...
@markc You are right, I think Mars needs to organize the forum a bit better.
@batalto As Suspected, It is a fit and forget configuration designed by Freedom Heat Pumps to prevent call backs due to the inability of their install...
Actually there has been little change from prior to MCS being launced appart from an indcrease in the price of installations by 2000-3000 pounds, ther...
@editor Actually Mars, it would make more financial sense to get your system fixed, you would not drive your car with flat tyres. There is not much ...
@batalto Unfortunately, if you do not do things properly, it may not work. Like trying to drive a car without pumping up the tyres. It is all there bu...
@derek-m I agree, unfortunately this industry is self-destructing and nobody seems to care, it is very frustrating. I hope, someone will read my con...
@batalto The pumps are more than likely too small and not capable of transferring sufficient water to deliver the heat. However, the buffer thank is...
@batalto Is it a 4 pipe one with a pump pumping round your radiators?
@batalto Do you have a buffer tank or system seperation?
- 26 Forums
- 2,364 Topics
- 53.6 K Posts
- 261 Online
- 6,027 Members
Join Us!
Worth Watching
Latest Posts
-
RE: Mitsubishi Ecodan R290 10kW performance
And to you too. Wishing you a very enjoyable festive s...
By Sheriff Fatman , 7 minutes ago
-
Assuming none of this contradicts anything that @transp...
By Sheriff Fatman , 15 minutes ago
-
RE: Setback savings - fact or fiction?
I have managed to get the data points in a scatter plot...
By cathodeRay , 2 hours ago
-
RE: External pipework insulation
They do? But that isn't apparent from the photos we'r...
By Transparent , 2 hours ago
-
RE: New Fogstar 15.5kWh upright solution
Inverters can pick up cell voltages and the overall bat...
By Transparent , 3 hours ago
-
RE: My Powerwall 3 Consumes 3-4 kWh/Day in Self-Consumption: Is This Normal?
@editor Thank you so much for looking into this for me ...
By Caron , 3 hours ago
-
RE: Solis S6-EH1P8K-L-PLUS – Why I Chose It and What I’ve Learned So Far
I've been looking at the S6-EH1P8K-L-PLUS, but put off ...
By energy9165 , 4 hours ago
-
RE: Speedcomfort radiator fans
Too expensive IMHO for a whole house, at this point do ...
By JamesPa , 4 hours ago
-
RE: Say hello and introduce yourself
@velcro welcome to the forums. Please feel free start a...
By Mars , 16 hours ago
-
Daikin EDLA11D3V3 DHW Settings
I have a newly installed EDLA11D3V3 which I'm still get...
By Velcro , 17 hours ago
-
@jamespa I have found that it comes as a shock when we ...
By Toodles , 19 hours ago
-
RE: Need Help Optimising My Rushed ECO4 Install: 12kW Bosch Heat Pump
Hi @mickamills . Welcome to the forum. It sounds like...
By bontwoody , 21 hours ago
-
RE: Midea ASHP – how to set weather compensation
@curlykatie did you get sorted with this?
By MickaMills , 21 hours ago
-
RE: Octopus Cosy Heat Pump Owners & Discussion Thread
The FT levels off at either the set point OR the minimu...
By AndrewJ , 2 days ago
-
RE: MyVaillant Connect Regular Disconnect
Thanks. Yes, if the time is consistently 11pm every nig...
By buckwem , 2 days ago
-
RE: Who's your electricity provider and what's your tariff?
@transparent Thanks, this helps. Could it be that St...
By Batpred , 2 days ago
-
RE: Clivet ASHPs and weather compensation
Simon did share a lot of very helpful advice. On furthe...
By ambris , 2 days ago
-