Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Sep 19, 2024
@johnmo The Mini Stores look great and would appear to be the solution to a problem, but would they get past the MCS criteria?
@iantelescope Could you please clarify why your heat pump stopped functioning yesterday afternoon.
@iantelescope How are you measuring the Power as shown in the graph?
@iantelescope Which shorting wire did you disconnect and why did you do so?
@iantelescope Ian, So that we can better understand what is happening within your system, could you please mark up your schematic diagram with the...
@jamespa You are probably correct. I'm trying to locate the settings (if they exist) that detail how high above required LWT or RWT the water temp...
@iantelescope I'm sorry to hear of your medical condition, we will try to keep you warm. What is your desired IAT? Can you please post the setting...
@lucia I forgot to mention that your heating system is dynamic, so it keeps changing and re-balancing. If the OAT starts to increase, then the therm...
You can ignore cells G6 and H6, they are just to estimate the required water temperature for a given wattage output. The reverse process so to speak. ...
You need to look at the radiator manufacturer's specification, which should state its output at DT50, that is an average water temperature of 70C when...
@iantelescope It may be useful if I explain the objectives, so that you can better understand why we request certain data. The room thermostat has...
@iantelescope Can you please close the valve so that the buffer tank is no longer in use.
- 27 Forums
- 2,797 Topics
- 66.1 K Posts
- 3,090 Online
- 7,199 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: 15kw pump for 225m2 1990's house - over kill?
@seaviews, welcome to the forums. I can understand why ...
By Mars , 12 minutes ago
-
BT cuts you off, Plusnet blames Openreach... welcome to “seamless” broadband switching
Rant alert!With everything getting more expensive, we’v...
By Mars , 37 minutes ago
-
RE: Octopus Cosy 12 Heat Pump Regret: Incredibly Loud, Poor Heating & Constant Hum - Help!
@editor FWIW my problem was resolved, eventually, after...
By BigFish , 39 minutes ago
-
My heating has been off and DHW on throughout the summe...
By DavidAlgarve , 3 hours ago
-
RE: Anyone concerned about GivEnergy?
The GivE forum seemed to have survived the collapse of ...
By downfield , 4 hours ago
-
RE: How quickly would you want/expect heat recovery to take from setback?
@singlespeed I had better explain how my radiators are ...
By Toodles , 5 hours ago
-
RE: Cooling/heating with one unit
@mrkfm The Solo has a small capacity and only suitable ...
By dgclimatecontrol , 5 hours ago
-
RE: Renewables & Heat Pumps in the News
The irony is there's already an established internation...
By Temperature_Gradient , 7 hours ago
-
First you need to know how much thermal energy you'll n...
By bobflux , 17 hours ago
-
RE: Renewable Heating Hub Homeowners' Q&A Podcast
Come for the low-carbon homes. Stay for George Clarke’s...
By Mars , 2 days ago
-
RE: How should the Boiler Upgrade Scheme be reformed?
Not quite, regular A2W heat-pumps need a load of extra ...
By Temperature_Gradient , 4 days ago
-
RE: Heat Geek installations: share your experiences
one thing i learnt from reading people’s comments and e...
By Batpred , 4 days ago
-
RE: Do I add Air Con or MVHR to existing A2W ASHP?
We have ‘signed on the dotted line’ today for a Panason...
By Toodles , 4 days ago
-
RE: Heat pump branding. Clever, contemporary… or a bit too much?
...or it was there and was lost thanks to laziness and ...
By Majordennisbloodnok , 4 days ago
-
Bufferless design & control of Chinese air to water monoblock hybrid heat pump in Alberta, Canada
This post is about how I successfully configured a buff...
By Tony.Stolz , 4 days ago