Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

cathodeRay
cathodeRay
@cathoderay
Moderator
Famed Member
Joined: Feb 28, 2022
Last seen: Sep 9, 2026
Topics: 18 / Replies: 3023
Reply
RE: 14kW Midea ASHP in an old leaky building

The other thing I noticed out of the corner of my eye but didn't record was the flow rate went up. Mine is normally glued to 1.4 something, but I thin...

4 years ago
Reply
RE: Samsung 12kw efficient running. The little tweaks.

@editor - Mars, a dozen tee shirts with "I woke up at 02:40 this morning to check my heat pump" emblazoned on them should definitely be included in th...

4 years ago
Reply
RE: Heat pump user survey

I first read that brand name/logo on the right hand side of the letter head as uemonia - only two letters short of pneumonia! They just have't got a c...

4 years ago
Reply
RE: 14kW Midea ASHP in an old leaky building

@batalto - I've just seen the Midea unit go through a defrost cycle on the Midea controller, I just happened to be looking at the LWT when it happened...

4 years ago
Reply
RE: 14kW Midea ASHP in an old leaky building

@mjr - I have given some thought to adding some sensors/automation, but as you say it is far from clear if they can be readily hooked into a Midea sys...

4 years ago
Reply
RE: Rate the quality of your heat pump design and installation

If that gets an average vote, I wonder, how bad do they have to be to to get a poor/absolutely shocking vote?

4 years ago
Reply
RE: Massive Electricity Cost

This is interesting. I have a similar age and construction house, but a lot smaller, near half the size, and I am using 40kWh/day, or also about £15/d...

4 years ago
Reply
RE: 14kW Midea ASHP in an old leaky building

@kev-m, @mjr, @mookyfoo, @derek-m - thank you all for your comments. I did do the setback over Sunday to Monday night (to 16 degrees on the kitchen ro...

4 years ago
Reply
RE: -5c this weekend!

My hope, if I ever need to do this, is that it will increase energy use and so costs (obvs, 14 => 16kW), but it should not adversely affect COP (mo...

4 years ago
Reply
RE: ASHP Retrofit in a 2015 house with 10mm radiator tails

In the meantime, I've tracked this down, it is the so called radiator exponent n equation, which is used by rad manufacturers to calculate their corre...

4 years ago
Reply
RE: 14kW Midea ASHP in an old leaky building

I'm putting this here because it is in effect a continuation of this thread. For the past week, I have been fine tuning my heating always on weather...

4 years ago
Reply
RE: ASHP Retrofit in a 2015 house with 10mm radiator tails

I had a number of installers take similar positions. They are jobsworths, hiding behind regulations. Solution? Fire them.

4 years ago