Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: May 16, 2026
I am impressed with the depth of knowledge in this thread.. I was not sure what setback is, now I know we have ours at 15C! Given the cold weather,...
Perhaps the link only works when logged in.. I will include it again. The Solis S6 cert docs can be found on the Ena website, via this link connec...
@transparent Just to be clear, when you set an export limit on all the inverters you have, do you set it as a maximum in amps? If a lim...
@transparent The link Solis shared and I pasted (pointing to the ena site) is expanded by the renewableheatinghub website, so the image below the t...
In the diagram below, I describe my understanding of the comms connections involved in a standard setup, where there are several batteries (I love dia...
If I snided back, I apologise. Competition is what keeps big companies like Fogstar on their toes. Whenever anyone suggests, implies or states tha...
I need to have a look out for it. I know IBM feeds some of the "databases" of other AI models, so spreading the wisdom!
@abernyte Thank you for sharing. Just wanted to make sure you are aware that feeding power into an RCD protected circuit may burn the solenoid i...
The aux port in option 2 (gen/smart port) is probably going to need to be live to allow AC coupling. Not having a CT clamp should not make any differe...
Having a heatpump on its own distribution board is great, if you have spare space. It may become easier to add to it. There are plenty of other opt...
I had a look at the SGI-2 that @transparent suggested, to evaluate the "fit" based on my understanding of James´ requirements: All generation / s...
A few things to consider, that I am sure you are already aware: the 50V DC connection between battery and inverter should be kept short. This redu...
- 26 Forums
- 2,634 Topics
- 61.5 K Posts
- 317 Online
- 7,030 Members
Join Us!
Latest Posts
-
RE: Setback savings - fact or fiction?
@jamespa — thanks. No rush, I posted a bit too hastily ...
By cathodeRay , 6 minutes ago
-
RE: My Grant R290 9kW Heat Pump Installation
I am following this thread with great interest and than...
By TaffontheTaff , 1 hour ago
-
Hi, @david999. I have a Growatt inverter too, so I have...
By Majordennisbloodnok , 3 hours ago
-
RE: Sizing an ASHP; Heat loss and kW
You can't measure heat loss with a website. But you ca...
By JamesPa , 16 hours ago
-
RE: Estimating true heat loss from twelve months of consumption data
@ian33a — I have a sort of residual interest in this pr...
By cathodeRay , 18 hours ago
-
Hi, Thank you. So its a Daikin Altherma 3M...
By Lbart68 , 21 hours ago
-
I have a Contactum CU. Would the below RCBO (descriptio...
By Batpred , 21 hours ago
-
RE: Samsung gen 7 HP 12kw - auto control issue and water law
@chainreaction Agree with @broadsman , it seems many ...
By Batpred , 22 hours ago
-
RE: Anyone concerned about GivEnergy?
@transparent Thank you and appreciate your timely reply...
By SUNNYSKIES , 23 hours ago
-
RE: Grant Aeona 3 R32 cycling with weather compensation.
The hot water heating looks normal. The heat transfer ...
By GrahamF , 1 day ago
-
RE: A2A vs A2W: Which Heat Pump Would You Pick?
Good questions @temperature_gradient. My understanding ...
By springswood , 1 day ago
-
RE: New Vaillant aroTherm Plus in black - When will it come to the UK?
All going according to plan, mid July we get that 7kW a...
By Batpred , 2 days ago
-
Current metrics - DHW target set to 47c
By TaffontheTaff , 2 days ago
-
RE: New Solar, Batteries, Air Source and Under Floor Heating advice please
You’re right: UFH works best with high-conductivity fin...
By bafab , 2 days ago