@knukes Hi, thanks for sharing. The Grant weather compensation parameters are quite straight forward to adjust once you get into the settings in the l...
Hi Chris, there's some fantastically experienced and knowledgeable ASHP people here, you've come to a good place for help. As others have said, based ...
@editor Yes, both by Thrift Energy
I don't think you're that far wide of the mark Mars in your estimate. 7/10 'could do better' would be my honest appraisal. ASHP: tidily installed wo...
@derek-m Hi Derek, the primary pump is the one in the ASHP, which for the Grant Aerona range is a fixed pump curve device. It's for exactly this reaso...
@derek-m, correct, the digital thermometers from Amazon Kev gave a link to. Nifty little things. Cost £11 or so on Amazon Prime for 4. The low loss he...
@kev-m Hi Kev, great minds. I've just fitted 4 of these to my newly installed system either side of the low loss header/volumiser, to read the primary...
@hughf The HIVE was by the installer, not Grant. It works for me as I can zone various rooms in the house on smart TRVs to boost temperatures to suit ...
@derek-m Yes. 50degC to 30degC heating water supply temperature depending on outdoor temperature. Weather compensation active from 20degC to -4degC. ...
Hi @Mars, yes, a brand new install. First winter off kerosene. I either needed to replace a 25yr old oil boiler, with a newer condensing oil burner, o...
@kev-m Thank you for the welcome. Grant Aerona 3 10kW ASHP. I have a 'by the book' install with a Grant low loss header, secondary pump, 250L pre-pl...
- 21 Forums
- 1,985 Topics
- 43.3 K Posts
- 13 Online
- 2,311 Members
Join Us!
Heat Pump Dramas?
Thinking about installing a heat pump but unsure where to start? Already have one but it’s not performing as expected? Or are you locked in a frustrating dispute with an installer or manufacturer? We’re here to help.
✅ Pre-Installation Planning
✅ Post-Installation Troubleshooting
✅ Performance Optimisation
✅ Complaint Support (Manufacturer & Installer)
Latest Posts
-
😆 I would have been tempted to see how good the...
By Mars , 6 minutes ago
-
I’ve circle your compressor output. It’s just going fro...
By davidnolan22 , 48 minutes ago
-
RE: Volumisers in Heat Pump Systems: Does Placement Matter?
No not auto adapt running hotter at cheaper times coole...
By Gary , 1 hour ago
-
RE: Ecodan Auto Adapt Questions
Hi @richard24738 we weren’t happy with our FTC Contr...
By SUNandAIR , 1 hour ago
-
RE: To relocate or add extra PV panels..advice required
You can't forecast the annual generation by simple extr...
By JohnR , 2 hours ago
-
@toodles whilst I agree with toodles the actions he de...
By Potatoman , 2 hours ago
-
RE: Plug and play solar. Thoughts?
They are 'exporting to the grid' within the EREC defini...
By Transparent , 3 hours ago
-
RE: Are MCS are finally improving (some of) their guidelines?
@johnr I think OE argue that the lower running costs as...
By Toodles , 4 hours ago
-
RE: Additional Battery v Wind Turbine v Ripple
@lucia Yes, that is the response to which I referred ea...
By Toodles , 5 hours ago
-
RE: Is it worth siting panels on an East facing roof?
Yes. Thanks all. I have used the guides and have found ...
By Carpenterstation , 22 hours ago
-
RE: The EPC Dilemma: How Current Ratings Fail Heat Pumps
I've commented earlier in this thread, finding the same...
By Mike Patrick , 1 day ago
-
RE: SolarPV tables / online calculator
This guy did a good analysis in summary go down a...
By Judith , 1 day ago
-
RE: ASHP Ecodan L9 error - No Heating but Hot Water
@dnagre delayed reply! It worked again for a bit but ha...
By Phoenix15 , 1 day ago
-
RE: Vaillant Arotherm Plus - new build no heating, no radiator
@john1756 did you ever get to the bottom of this?
By Mars , 1 day ago
-
RE: Aira Heat Pump: Stylish Scandinavian Heating
We tested the away mode for the first time as we were a...
By ChandyKris , 2 days ago
-
RE: Confused about Samsung Gen6 Hot Water Controller
Found a copy on this really good website 🤣 ...
By DerekDeLeon , 2 days ago
-
RE: Smart TRV experiences (ideally integrating with Midea heat pump)
@madbilly - I think you may risk over-complicating this...
By cathodeRay , 2 days ago
-
RE: Nibe F2040 ASHP PCB failure
@editor that is awesome! Your help is much appreciated.
By Delta , 2 days ago
-
In our case the pipe run for the heat pump is short and...
By madbilly , 2 days ago
Latest Topics
-
Plug and play solar. Thoughts?
By Lucia 2 days ago
-
By JamesPa 2 days ago
-
Vaillant water pressure gauge vs Analogue gauge
By jeegnesh 2 days ago
-
Database of heat pump performance data?
By madbilly 3 days ago
-
By madbilly 3 days ago
-
Confused about Samsung Gen6 Hot Water Controller
By ntruby 4 days ago
-
help with new bathroom and towel radiator
By AdamK 4 days ago