@lfranklin used to divert excess solar PV generation into a system hot water tank via the 3kW immersion. About £350-400. Friends with them have said t...
@lfranklin ah, yes, you'll need a smart meter for Cosy. My PV export tariff is 'Outgoing Octopus 12M fixed' their standard 15p/kWh fixed arrangement. ...
Have you got a variable rate tariff and have scheduled the Growatt battery to charge during cheap rates to supply during standard and peak rates? It's...
@katcesca what flow temperature has your MCS estimate based and sized the design on? This is THE most fundamental element of an ASHP efficiency and th...
@marvinator80 you got lucky on the SAP EPC lottery! I went up from a D to a C. My heating and hot water scores both went DOWN after ASHP and solar wit...
@mike-patrick - click on 'document' @ronin92 - clearly whoever is in charge at the BRE and tasked with preparing the SAP methodology for heat pump e...
@marvinator80 ahhh, right, check the cylinder stat. Here's the info for that stat in Appendix A p.30. When the stat is demanding heating, the green LE...
@hughf refrigerant charge quantity is critical. The best place to charge the unit is in the factory when built, where equipment is calibrated and cont...
I would use the ASHP for HW generation, as, even accounting for the fairly slow pre-heat time when the flow through the ASHP cools a bit before warmin...
"He's got heat meters fixed to the pipework. Room temperature monitors" @mjr they got thrown under the BUS. The current BUS scheme requires no energ...
@andris EPCs can be a load of rubbish, my EPC when I was heating by oil rated my main heating and hot water was 'average' with a boiler that was 80% e...
@marvinator80 sounds all good. Pleased it has gone well. My wallet-busting 260kWh consumption last week was offset a little by a decent 60kWh solar PV...
- 21 Forums
- 1,977 Topics
- 43.1 K Posts
- 46 Online
- 2,305 Members
Join Us!
Heat Pump Dramas?
Thinking about installing a heat pump but unsure where to start? Already have one but it’s not performing as expected? Or are you locked in a frustrating dispute with an installer or manufacturer? We’re here to help.
✅ Pre-Installation Planning
✅ Post-Installation Troubleshooting
✅ Performance Optimisation
✅ Complaint Support (Manufacturer & Installer)
Latest Posts
-
@sandman1600 it sounds like they have just tired to...
By davidnolan22 , 3 minutes ago
-
RE: Volumisers in Heat Pump Systems: Does Placement Matter?
@abernyte no, it doesn’t turn the pumps off on mine.
By davidnolan22 , 1 hour ago
-
RE: Confused about Samsung Gen6 Hot Water Controller
Do you have the DHW on timed periods or on continuous w...
By DerekDeLeon , 10 hours ago
-
RE: What is the best strategy for operating a very oversized heat pump?
I think we are currently operating a weird mix of 2 and...
By guthrie , 13 hours ago
-
We’ve had our heat pump (EBAC) since October, with a fe...
By Simon and Zoe , 14 hours ago
-
RE: DHW temp Samsung AE120RXYDEG 12kw ASHP with Gen 6 controller
@Bami Ive had a look for the specs of your cylinder o...
By bontwoody , 15 hours ago
-
RE: best approach for primaries?
Personally I would want them inside the heated envelope...
By JamesPa , 17 hours ago
-
RE: help with new bathroom and towel radiator
I persuaded my installer that heat loss from the adjace...
By JamesPa , 18 hours ago
-
RE: Grant Aerona fine tuning advice needed
Thank you pretty sure it's solar gain causing the incre...
By Stopbar , 19 hours ago
-
-
RE: Heat Pump Servicing & Maintenance – Good Value or Rip-Off?
I fitted a Samsung 8kw myself on a new build with under...
By DerekDeLeon , 22 hours ago
-
RE: Who's your electricity provider and what's your tariff?
@adrian it does look like they’ve updated their outgoin...
By Arundalep , 2 days ago
-
RE: Heat Pump Sizing & Installation Costs
1970s 4-bed detached house approx 168 sq.m internal are...
By JohnR , 2 days ago
-
RE: Is it KISS or constant – weather compensation vs. set flow temperature?
Away at present. Hence the delay. Will get back asap. ...
By cliffhanger , 2 days ago
-
RE: Setback savings - fact or fiction?
The lower the DT the higher the flow rate. The lower ...
By BobTSkutter , 3 days ago
-
RE: New kitchen with no walls – will fan coil units work?
Thanks. That explains the strangely-shaped 'feet' (loo...
By IanMK13 , 3 days ago
-
RE: Heat Pump Books For Beginners – Bodge Buster & From Zero To Heat Pump Hero
I’ve updated Bodge Buster for 2025 to empower homeowner...
By Mars , 3 days ago
-
RE: Aira Heat Pump: Stylish Scandinavian Heating
Aira, the Swedish, end to end manufacturer, system desi...
By KevinPotts , 3 days ago
-
Unfortunately for your argument the best performing Dai...
By RobS , 4 days ago
-
RE: Grant ASHP not reaching target temperatures
@mikefl Thank you. I’m not sure how to do these checks ...
By Hillswick , 4 days ago
Latest Topics
-
Confused about Samsung Gen6 Hot Water Controller
By ntruby 11 hours ago
-
help with new bathroom and towel radiator
By AdamK 22 hours ago
-
Grant Aerona fine tuning advice needed
By Stopbar 2 days ago
-
Adjusting 6kW Daikin's Weather Compensation Curve
By Ubert767 5 days ago
-
Should I make my radiators smaller?
By Scalextrix 6 days ago