Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

AllyFish
@allyfish
Contributor
Prominent Member
Joined: Oct 31, 2022
Last seen: Mar 16, 2026
Topics: 23 / Replies: 494
Reply
RE: DIY Heat Pumps.

I think it's a monobloc unit, R410A. See here:which is probably why they are getting flogged off cheap by the likes of Appliances Direct, to unsuspect...

3 years ago
Reply
RE: DIY Heat Pumps.

With a DIY install you've got the option for heating and also cooling via fan coil units, which under the MCS approach isn't an option. However, these...

3 years ago
Reply
RE: Long burning briquettes

Yeah, exactly my concern. What are the briquettes made of (waste product or felled timber) and how much CO2 and energy goes into their process that pr...

3 years ago
Reply
RE: Long burning briquettes

I've looked at this company several times but never taken the plunge. They get good reviews. My only concern is the Lekto supply chain is opaque, they...

3 years ago
Reply
RE: Heat pump research study: UK homeowners that decided not to install a heat pump after considering it

@editor is it s survey intended to, ultimately, improve the take up of ASHP and renewable heating? Or a survey by an organisation with a vested intere...

3 years ago
Reply
RE: Battery Charging Anomalies

In my day job I'm designing systems that support fire-rated battery rooms with 200kVA Siemens Bluevault Li-Ion 230V UPS batteries. They require a room...

3 years ago
Reply
RE: DHW with Grant Aerona link to cylinder temperature

@fjj 52degC is a good thermostat setting, the flow from the ASHP needs to be 3-5degC higher than the tank cylinder setting thermostat or you're just b...

3 years ago
Reply
RE: Rate the quality of your heat pump design and installation

Seems to be the norm. Decent install on the wet side with monobloc and rads. Usual mediocrity with the rest: Condensate drainage overlooked, check. ...

3 years ago
Reply
RE: DHW with Grant Aerona link to cylinder temperature

@FJJ, I have the same set up. Grant 10kW Aerona, pre-plumb 250l cylinder, iBoost. The iBoost just runs on the 3kW immersion heater, which I don’t thin...

3 years ago
Reply
RE: Eco Heatsense: a game changing radiator valve

@derek-m or a bag of sparks, or a box of rivet holes, or some sky hooks. I fell for the lot when I served my time.

3 years ago
Reply
RE: This does not make sense - documents needed for EPC score

@ronin92 that's a good find, thank you. Having had a speed-read of the research paper, it seems the elephant in the room may be the simple affordabili...

3 years ago
Reply
RE: What impact does compressor not running at low LWT have?

Welcome @mortstar. 🙂 Compressors are very well protected in ASHPs, and user and installer configurable setting adjustments to the water side controls...

3 years ago