Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Jan 10, 2026
@jamespa So settings to date are as follows for now. - **2011:** -10°C- **2012:** 15°C- **2021:** 40°C- **2022:** 25°C I have put 2022 to 38c Wi...
At long last , I found a decent plumber and boiler expert locally to take the buffer out of the system(his advice) and change the piping the short dis...
OK , Thanks James, can the btu's be calculated from the existing Radiator as it was measured to size for that room initially. By the way I have a pl...
I have messaged you . Thank you in anticipation of your help .
The old problem we had certainly was not right , but while it was using TRV's and open lockshieldsand the buffer, the costs were more controlled but s...
Ok Guys James, I cannot get anyone to respond to a request locally to come and have a look at converting a buffer tank to a Volumizer therefore elim...
Sorry random input , must of thought I was on another thread!!
No I don’t know what volume, I might look at the sheets again. Is it normal to have it recorded somewhere? It maybe somewhere as the system has had gl...
@ubert767 Thanks , no wonder I get too much of a temp drop , mine is 200L , too much mixing .
@ubert767 the removal of the 20ltr. 4 port buffer out of interest,is that 20l or 200l ? I am planning bypassing my buffer , still waiting for ...
- 27 Forums
- 2,810 Topics
- 66.4 K Posts
- 3,395 Online
- 7,216 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Adding data centre electricity costs to domestic energy bills?
Data centres gave large roof surface, so they are asked...
By Batpred , 3 minutes ago
-
RE: Why don't people choose heat pumps?
Trianco activair 3kW. Also several A2A models most no...
By JamesPa , 4 minutes ago
-
Someone will say that they can mix up to 5% in the gas ...
By Batpred , 28 minutes ago
-
RE: How much of your renewable and home setup would still work if the internet went down?
I wonder if worth evaluating what happens if our local ...
By Batpred , 37 minutes ago
-
RE: Electricity price predictions
I wasnt sure where to post An interesting meeting ...
By Jeff , 14 hours ago
-
RE: Boiler Upgrade Scheme funding reduced by circa £750 million in 2026 budget
Agree with everything else. Personally I think the as...
By JamesPa , 22 hours ago
-
RE: Aerotherm and weather compensation
@jamespa I replied yesterday with detailed readings whi...
By DavidB , 1 day ago
-
RE: Octopussy cosy 6 experience
@paultheheating Unless things have changed more recentl...
By Toodles , 2 days ago
-
RE: Marvel Heating liquidation
@editor This is an important point. each winter, you...
By davidnolan22 , 2 days ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
Very nice. we’ve been super soggy here, but rather m...
By Papahuhu , 3 days ago
-
RE: DIY powerflushing tutorial
Interesting! I toyed with the idea too. But I installed...
By bobflux , 3 days ago
-
RE: 15kw pump for 225m2 1990's house - over kill?
@seaviews Agree with the others on sequence: loft first...
By mk1234 , 3 days ago
-
RE: The Changing Jet Stream Could Challenge UK Air Source Heat Pumps
@etchedpixels Agreed, just a thought for others. I am...
By Watcher , 4 days ago
-
RE: Vaillant ecoTEC Plus - Flow Temp and Set Up
Heating been on for 4 weeks now, continuous. It's 6C o...
By trebor12345 , 5 days ago