Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

william1066
@william1066
Member
Estimable Member
Joined: Jan 5, 2023
Last seen: Feb 13, 2024
Topics: 0 / Replies: 206
Reply
RE: Numerous issues – 11kW Daikin Altherma 3

I can't think why it would. Heat will always travel towards colder areas, so you would now have to put more heat into the room you are heating becaus...

3 years ago
Reply
RE: Numerous issues – 11kW Daikin Altherma 3

From what I understand, this is a 260 sqm new build. @200mm centers this is 1300m of pipe @150mm centers this is 1735m of pipe The exposed pipe,...

3 years ago
Reply
RE: Numerous issues – 11kW Daikin Altherma 3

Whoever suggested that needs to do "the maths". I would like to know how much heat a couple of meters of 22/28mm pipe emits when carrying water at 35 ...

3 years ago
Reply
RE: A Beginner's Guide to ASHP Monitoring

It is normal for all devices to default to DHCP. With IPv6 there may be better options, I don't have much knowledge of IPv6. Now imagine if anyone c...

3 years ago
Reply
RE: Numerous issues – 11kW Daikin Altherma 3

Only your bedrooms should be set to close the UFH circuit as you will likely want your bedrooms to be at a lower temperature than the rest of the hous...

3 years ago
Reply
RE: Numerous issues – 11kW Daikin Altherma 3

I did not manage the entire thread and did not see your heat loss calculations. A passiv house will be 15w per sqm, mine averages 60w per square mete...

3 years ago
Reply
RE: Connecting Home Assistant to a Midea Heat Pump

@transparent Please share your results with the above device. I am getting significant noise from my 10k thermistors. I think these [thermistors on ...

3 years ago
Reply
RE: A Beginner's Guide to ASHP Monitoring

I don't think this is specific to HA and is definitely not a flaw. For most, if not all, devices you put onto your network you will have to decide be...

3 years ago
Reply
RE: Samsung ASHP scheduling help

Are you splitting DHW from Heating CoP? Also you really need to measure CoP vs outside temperature using scatter plot

3 years ago
Reply
RE: Samsung ASHP scheduling help

I have run a POE Ethernet to my electric box, with the olimex poe esp32 feeding home assistant, an open energy monitor pulse counter on the din rail p...

3 years ago
Reply
RE: Samsung MIM-E03CN Gen 6 Advice Needed for DHW Settings

I would be interested in more details here, if you have time to share. Thanks

3 years ago