Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Oct 19, 2026
Profitable perhaps...... but not grid friendly unless you're on a 3-phase supply. What export limit has your DNO allowed you to have? Have a look ...
A mains supply to an inverter can com,ply with 18th Edn, and yet still not have a bi-directional RCBO. The issue was addressed in a separate addendu...
Depending on what 'Standards' existed when you made that mains connection, it may or may not be "safe". Have a look at the Safety Warning discussion...
Erm... not quite. Modbus describes the language used for the commands to be sent and received.There is a universal standard for this, but BMS units ...
If only there was some sort of online help-forum where people could offer you advice 😉 Just how do you think the rest of us worked out how ...
You could relocate a storage battery to a new house if you wanted to! Although Fogstar seem to no longer offer DIY Assembly options,battery enclosur...
@editor - here's my take on your December generation figures:
I concur with that analysis. If the PV panels are resting at ground level, and not embedded into it, then you don't require planning permission.Loca...
Running the power-leads in parallel is OK,but not so for the data cables, whether they be CANbus or RS485. Before needlessly diving into the technic...
Yes! Well... maybe not an entire forum dedicated to discounted tariffs, but a topic would certainly be of interest. 😉 We can make a link to ...
Then, perhaps @toodles , you should've made a submission on that point when DESNZ ran a Public Consultation on the Governance of their SSES Strategy 3...
The strategy of a 3rd-party having (remote) control over devices in the home is in line with Government Policy. It's understandable that two British...
- 27 Forums
- 2,796 Topics
- 66.1 K Posts
- 2,754 Online
- 7,199 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
My heating has been off and DHW on throughout the summe...
By DavidAlgarve , 24 minutes ago
-
RE: Anyone concerned about GivEnergy?
The GivE forum seemed to have survived the collapse of ...
By downfield , 1 hour ago
-
RE: How quickly would you want/expect heat recovery to take from setback?
@singlespeed I had better explain how my radiators are ...
By Toodles , 2 hours ago
-
RE: Cooling/heating with one unit
@mrkfm The Solo has a small capacity and only suitable ...
By dgclimatecontrol , 2 hours ago
-
RE: 15kw pump for 225m2 1990's house - over kill?
Firstly you have come to the right place and its good t...
By JamesPa , 2 hours ago
-
RE: Renewables & Heat Pumps in the News
The irony is there's already an established internation...
By Temperature_Gradient , 4 hours ago
-
First you need to know how much thermal energy you'll n...
By bobflux , 14 hours ago
-
RE: Renewable Heating Hub Homeowners' Q&A Podcast
Come for the low-carbon homes. Stay for George Clarke’s...
By Mars , 2 days ago
-
RE: Octopus Cosy 12 Heat Pump Regret: Incredibly Loud, Poor Heating & Constant Hum - Help!
@razz, as we head into the heating season, I just wante...
By Mars , 2 days ago
-
RE: How should the Boiler Upgrade Scheme be reformed?
Not quite, regular A2W heat-pumps need a load of extra ...
By Temperature_Gradient , 4 days ago
-
RE: Heat Geek installations: share your experiences
one thing i learnt from reading people’s comments and e...
By Batpred , 4 days ago
-
RE: Do I add Air Con or MVHR to existing A2W ASHP?
We have ‘signed on the dotted line’ today for a Panason...
By Toodles , 4 days ago
-
RE: Heat pump branding. Clever, contemporary… or a bit too much?
...or it was there and was lost thanks to laziness and ...
By Majordennisbloodnok , 4 days ago
-
Bufferless design & control of Chinese air to water monoblock hybrid heat pump in Alberta, Canada
This post is about how I successfully configured a buff...
By Tony.Stolz , 4 days ago