Search with Wattson
Activity
 
Notifications
Clear all

Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

Transparent
Transparent
@transparent
Moderator
Illustrious Member
Joined: Jan 20, 2022
Last seen: Sep 6, 2026
Topics: 16 / Replies: 3368
Reply
RE: Running from backup generaor in powercut?

Fortuitously, I've just posted here on another topic about buying a (cheap) clamp multimeter.

8 months ago
Reply
RE: Is it normal to use power from the grid when running off the battery?

The most popular make of multimeter purchased on AliExpress is Aneng. Search for Aneng clamp multimeter and you'll get a wide range of products and ...

8 months ago
Reply
RE: Is it normal to use power from the grid when running off the battery?

Feedback on your description above. I hadn't expected that the Eastron meter would be given its own 3-ph breaker!Is that because the electrician dec...

8 months ago
Reply
RE: Running from backup generaor in powercut?

Us Moderators have had a (private) discussion in 2025 about peak current demand from heat-pumps. It certainly used to be the case that there was hig...

8 months ago
Reply
RE: Exploring the role of alternative clean heating solutions - Government Consultation

Yes, I agree that the dearth of public knowledge of energy issues is a major reason why there is so little engagement with future energy strategy........

8 months ago
Reply
RE: Exploring the role of alternative clean heating solutions - Government Consultation

There's more to gain by submitting a personal response.It's extremely rare for individuals to respond to Government consultations. It looks like thi...

8 months ago
Reply
RE: Running from backup generaor in powercut?

Interesting question. The usual assumption is that generation sources based on mechanical rotation will naturally provide genuine sine-wave output. ...

8 months ago
Reply
RE: Is it normal to use power from the grid when running off the battery?

The Eastron SDM630 range is known to me.I have one here, but it's still in the box awaiting a monitoring trial which has yet to start. Your meter wi...

8 months ago
Reply
RE: Solis inverters S6-EH1P: pros and cons and battery options

Or alternatively, forget the need to get entrenched with compatibility lists,and instead get acquainted with the Open Modbus Standards and certificati...

8 months ago
Page 40 / 283
Share:

SPONSORS

Join Us!

Installer Finder

Degrees of Separation

Latest Posts

SPONSORS

Members Online

 No online members at the moment

Click to access the login or register cheese
Protected By
Shield Security PRO