Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

TechnoGeek
TechnoGeek
@technogeek
Member
Estimable Member
Joined: Aug 4, 2023
Last seen: May 28, 2026
Topics: 5 / Replies: 172
Reply
RE: Low temperature heating - does it feel like heat is more evenly distributed?

@guthrie I have a balancing act with my system because it is a bivalent set up. Oil boilers like a duty cycle of 3 cycles per hour unlike gas wh...

2 years ago
Reply
RE: Low temperature heating - does it feel like heat is more evenly distributed?

@toodles Yes I have noticed a more even heat distribution since installing my heat pump (12Kw Samsung Gen6). I have a particular problematic room (als...

2 years ago
Reply
RE: Time to seriously consider the Homely System perhaps?

@derek-m I wish it was! 🤣 Sadly due to the HP and controller being located within the outside boiler room, running the data cable for the built in the...

3 years ago
Reply
RE: COP for DHW using a heat pump

@redzer_irl From my own research over the last few weeks I would be inclined to agree with Glyn Hudson. I think for me, I incorrectly interpreted th...

3 years ago
Reply
RE: ASHP decision: Should I or shouldn't I?

@cookie197 For your information you can get slimline versions of HP tanks. I am looking at one at present as it needs to fit in the space currently oc...

3 years ago
Reply
RE: ASHP decision: Should I or shouldn't I?

@cookie197 Welcome to the forum! Reading about your decision dilemma I have been through a similar experience over the last 12 months. To echo the p...

3 years ago
Reply
RE: COP for DHW using a heat pump

@derek-m yes I do have an immersion heater however it is positioned at the top of the tank and would not be heating the same volume of water sadly. In...

3 years ago
Reply
RE: COP for DHW using a heat pump

@abernyte I did think of the oil boiler efficiency however it is a well maintained 5 year old Grant Vortex Blue flame and very efficient, so ruled 35...

3 years ago
Reply
RE: COP for DHW using a heat pump

@kocta Being the curious engineer that I am, I decided to do a little experiment with my metered oil boiler and heat pump and got some further questio...

3 years ago
Reply
RE: Say hello and introduce yourself

@transparent yes your assumption is correct it is an Octopus tariff and the PowerUp scheme which started 14th August is an Octopus scheme trial with t...

3 years ago
Reply
RE: Say hello and introduce yourself

@transparent Hope your good? Hoping the following will be of interest to you and other readersTo conclude this solar tube topic I decided for our part...

3 years ago